Lab report, NYS DOH & FDNY, WTC rubble, Oct 2001

Machine-extracted title · confidence 52%

FDNY asbestos and dust TWA sampling at WTC site, Oct 2001.

NYC-WTC_000348353–000348355
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Bu lk # 5 (NL) coating on 4' NA asbestos-chrysotile 15% NA X 2' steel silica 1.0% beam on lead <= 0.01 % rubble pile iron 1.5% aluminum 2.6 % copper ND magnesium 5.7% sulfur 3.4 % calcium Bsassasassssssssssssss: 21%

TWA = Time Weighted Average PEL = Permissible Exposure Limit PESH = NYS Public Employee Safety and Health Bureau f/cc = Fibers per Cubic Centimeter ppnii = parts per million mg/m^ = milligrams per cubic meter ug/m’ = microgram per cubic meter STEL = Short Term Exposure Limit Peale = Highest Level Seen During Test ND = not detected NA = not Applicable % = Percent = Less Than = Less Than or Equal To ** = Metals scan also included; Aluminum, Chromium, Copper, Iron, Magnesium, Mangenese, Molybdenum, and Nickel. rknalytical Method for total dust is based on NIOSH 0600 Analytical Method for silica is based on OSHA ID 142 and NIOSH 7500 Analytical Method for metals is based on OSHA ID 125G * = Sample result based on analytical method NIOSH 7400. This method utilizes Phase Contrast Microscopy (PCM) which counts ALL FIBERS longer than 5 microns in length and have a length to width ratio equal to or greater than 3:1. ’ = Sample result based on analytical method NIOSH 7402. This method utilizes Transmission Electron Microscopy (TEM) to identify and quantify asbestos fibers present. ’ = (Cassette sample was overloaded for the purpose of TEM analysis * = The Action Level for lead is 0.030 mg/m’ ’ = silica containing materials are generally considered as silica dust when the % silica is > 1%. ‘ = The Ceiling Limit for carbon monoxide is to be measured over a 5 minute sample. ’ = Results may include soluble non-sulfuric acid sulfate compounds

CITY_21MC100_011087972

NYC-WTC_000348355

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348355Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →