WTC Background Study Interim Final, March 2003

Machine-extracted title · confidence 25%

WTC background study interim final report prepared for FEMA and EPA contractors.

NYC-WTC_000418482–000418566
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

and the common areas (3%) were similar, as were the range of detection and mean concentrations. Based on the similarity of the data sets between spaces and between surfaces, it is recommended to use the entire data set, combined for surfaces, to estimate the background concentration. The 95% UCL from this data set provides a value of 103.7 g/fC as an estimate of the background concentration of cristobalite on hard surfaces.

6.3.1.3 Tridymite Bulk Dust - There were nine bulk dust samples collected from residential areas. These samples were analyzed for tridymite. There were no bulk samples collected from common areas. None of the samples detected tridymite above the detection limit. However, since the detection limit for the samples varied slightly, a theoretical background concentration can be calculated. The 95% UCL for tridymite in bulk dust is 4.69%, and this value can be used as an estimate of the background concentration.

Air - There were forty-six air samples collected with thirty-two collected from residential areas and fourteen collected from common areas. The samples were analyzed for tridymite. Tridymite was not detected in any sample. However, since the detection limit for the samples varied slightly, a theoretical background concentration can be calculated using the entire combined data set from the residential and common areas. The 95% UCL for the combined data set is 9.3 g/m^, which can be used as an estimate of the background concentration of tridymite in air.

Wipe - There were 114 wipe samples collected with eighty collected from residential areas and thirty-four collected from common areas. The samples were collected from hard surfaces including counters, floors, and walls. The samples were analyzed for tridymite. Tridymite was not detected in any sample, however since the detection limit for the samples varied slightly, a theoretical background concentration can be calculated using the entire combined data set for all surfaces from the residential and common areas. The 95% UCL for the combined data set is 99.8 g/ft‘, which can be used as an estimate of the background concentration of tridymite on hard surfaces.

6.3.2 Calcite Bulk Dust - There were nine bulk dust samples collected from residential areas. These samples were analyzed for calcite. There were no bulk samples collected from common areas. Only one of the samples detected calcite above the detection limit. The 95% UCL for calcite in bulk dust is 3.41% and this value can be used as an estimate of the background concentration.

Air - There were forty-six air samples collected with thirty-two collected from residential areas and fourteen collected from common areas. The samples were analyzed for calcite. Calcite was not detected in any sample. However, since the detection limit for the samples varied slightly, a theoretical background concentration was calculated using the entire combined data set from the

WORLD TRADE CENTER BACKGROUND STUDY 29

CITY_21MC100_012423937

NYC-WTC_000418516

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418516Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →