WTC Background Study Interim Final, March 2003

Machine-extracted title · confidence 25%

WTC background study interim final report prepared for FEMA and EPA contractors.

NYC-WTC_000418482–000418566
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Although the value estimated above has been identified as the recommended background concentration, an additional calculation was conducted without the elevated value to determine a UCL that is not influenced by the elevated value. The 95% UCL for the residential data that has the elevated value removed is 7.8 g/m\ This value may be more representative of background, however it is unclear how common the elevated value may be in an urban environment, therefore the recommended UCL is 61.9 g/m ' with the recognition that it may be much lower (i.e., 7.8 g,W).

Wipe - There were 114 wipe samples collected with eighty-one collected from residential areas and 33 collected from common areas. The wipe samples were collected from hard surfaces including counters, floors, and walls. The frequency of detection between the residential areas (38%) and the common areas (61%) for combined surfaces are not similar and the mean concentration for each type of Revised May 14,2003 surface sampled are not similar between the residential and common areas. Since the primary focus of this Study was to determine background concentrations for residential areas, it is recommended to use the data set for the residential spaces to estimate the background concentration. The mean concentrations from each of the surface types in the residential data set are similar, varying by less than a factor of two, therefore it is recommended to use the entire residential data set, which includes the results from the counters, floors, and walls. The 95% UCL for this data set is 79.6 g/ft^. This value can be used as an estimate of the background concentration for alpha-quartz on hard surfaces.

6.3.1.2 Cristobalite Bulk Dust - There were nine bulk dust samples collected from residential areas. These samples were analyzed for cristobalite. There were no bulk samples collected from common areas. None of the samples detected cristobalite above the detection limit. However, since the detection limit for the samples varied slightly, a theoretical background concentration can be calculated. The 95% UCL for cristobalite in bulk dust is 4.69% and this value can be used as an estimate of the background concentration.

Air - There were forty-six air samples collected with thirty-two collected from residential areas and fourteen collected from common areas. The samples were analyzed for cristobalite. Cristobalite was not detected in any sample. However, since the detection limit for the samples varied slightly, a theoretical background concentration can be calculated using the entire combined data set from the residential and common areas. The 95% UCL for the combined data set is 9.3 g/m^ which can be used as an estimate of the background concentration of cristobalite in air.

Wipe - There were 114 wipe samples collected with eighty samples collected in residential areas and thirty-four in common areas. The samples were collected from hard surfaces including counters, floors, and walls. The samples were analyzed for cristobalite. The frequency of detection for the residential areas (0%)

WORLD TRADE CENTER BACKGROUND STUDY 28

CITY_21MC100_012423936

NYC-WTC_000418515

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418515Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →