Air - There were sixty-two air samples collected, forty-eight in residential spaces and fourteen in common spaces. Each of the samples were analyzed using Phase Contrast Microscopy (PCM), Transmission Electron Microscopy (TEM) AHERA, and TEM Phase Contrast Microscopy equivalents (PCMe) methods.

PCM - There was a higher percentage of detections in the common space areas (71 %) than in the residential areas (42%) although the minium and maximum detected concentrations were the same. The UCL for the common area (0.0058 f/cc) is slightly more than twice the value for the residential area (0.0023 f/cc). This difference may not be an unusual occurrence as common areas, such as laundry rooms and hallways may contain more fibrous material, especially in laundry rooms and high traffic areas. Since the common space areas and the residential areas differ, it is recommended to use the 95% UCL for the residential spaces of 0.0023 f/cc as the background value.

TEM AHERA - There was a higher percentage of detections in the common space areas (14%) than in the residential areas (4%) although the minimum and maximum detected concentrations were the same. In addition, the mean for each data set were similar. The four samples (two common area and two residential) that had detectable concentrations of asbestos were at the detection limit of 0.0004 s/cc. Since the frequency of detection was marginally different for the common space areas and the residential areas, it is recommended to use the 95% UCL for the residential spaces of 0.00024 s/cc as the background value.

TEMPCMe - There was a higher percentage of detections in the common space areas (7%) than in the residential areas (4%) although the minimum and maximum detected concentrations were the same. In addition, the mean for each data set were almost equal. The three samples (two common area and one residential) that had detectable concentrations of asbestos were at the detection limit of 0.0004 s/cc. The UCL for the common areas (0.00029 s/cc) is marginally higher than the UCL for the residential area (0.00024 s/cc). The combined data set yields a UCL that is the same value (0.00024 s/cc) as the residential UCL. Given that the residential areas and the combined data sets provide the same UCL, it is recommended to use the 95% UCL of 0.00024 s/cc as the background value.

Microvacuum - There were 162 microvacuum samples collected, with 144 from residential areas and 18 from common spaces. The microvacuum samples were collected from porous materials, such as carpets, area rugs and couches. These samples were analyzed for asbestos. The results from these analyses were quite variable between different surfaces and between the different spaces. Asbestos was detected more frequently in the common spaces (22%) and at higher concentrations (mean = 7,145 s/cm^) than in the residential spaces (4%) with a mean concentration of 2,234 s/cm\ In addition, the carpets in both spaces had greater mean concentrations than the other porous surfaces (i.e., couches, chairs, and drapes). As the purpose for collecting microvacuum samples for asbestos WORLD TRADE CENTER BACKGROUND STUDY 23

CITY_21MC100_012423931

NYC-WTC_000418510

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418510Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

Compare copies and versions →