NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 85 pages

Chain-of-custody: 21 West Street air samples, Feb 2002

Machine-extracted title · confidence 33%

Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.

NYC-WTC_000418335–000418419
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS. INC. 200 Park Avenue South, Suite 1D01, New York, New York 10003 Phone: (212) 420-8119 Faxi (212) 420-6092 Project No.: 01-2039 Rose Associates ELAP Lab Code: 11029 Analyte: FIBERS 200 Madison Avenue NIOSH and AIHA Lab Code: 100273 Date Received: 9/17/01 New York, NY 10016-3901 NVLAP Lab cude: 101953 Date Analyzed: 9/18/01 Batch #: 01O9A6Z9 SUMMARY OF ANALYTICAL RESULTS Site: 21 H/esf Street, New York, NY

SAMPLE# COLLECTED DESCRIPTION I LOCATION TIME(min) VQLUME(h FIB/FIELD RESULTS(f/cc) LAB#

001 Ambient/ Apartment #3E/ Bedroom - North 120 1847 5/100 O.OOKLOD 17-SeptetTiber A 6223

002 Ambient/ Hallway/ @ Apartment #3E 120 1847 2/100 <0,001 <LOD 17-Septemher A 6224

003 Ambient/ Hallway/ By Apartment #9L 120 1847 14/100 0,004 17 September A 6225

004 Ambient/Apartment #9 L/Bedroom 120 1847 05/100 0.017 17-September A 6226

005 Ambient/ Apartment #22K/ Bedroom 120 1847 50/100 0,013 17-Se plember A 6227

006 Ambient/ Hallway/ By Apartment #22K 120 1847 51/100 0.014 17-September A 6228

Sample Analysts by: <LOD = Less than limit of detection which is 5,5 Fibers/100 Fields Positive Phase Contrast Microscopy (PCM) VOID1 = H.C.P. ( High Concentration of Particles) VOID2 = OvsrloadBd Method of Sample Preoaration and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994 ma, , „ Instrumentatian: Al wanner Olympus PCM Model BH-2with Walton-Beckett Graticule (lOOum field diameter). Laboratory Director

Report Date: September 18, 2001 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this math gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and ail claims arising out of JLC's analysi these samples are limited In recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs b the above. Page 1 of 2

05080

CITY_21MC100_011971023

NYC-WTC_000418415

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418415Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →