Chain-of-custody: 21 West Street air samples, Feb 2002

Machine-extracted title · confidence 33%

Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.

NYC-WTC_000418335–000418419
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document y rr?:.'

JLC ENVIRONMENTAL CONSULTANTS, INC, 200 Park Avenue South, Suite 1001, New York, New York 10003 ! Phone: (212) 420-8119 Fax: (212) 420-6092 ProjectNo.: 01-2059 Rose Associates ELAP Lab Code: 11029 Analyte: FIBERS 200 Madison Avenue NIOSH and AIHA Lab Code: 100273 Date Received: 10/5/2001 New York. NY 10016-3901 NVLAP Lab Code: 101953 Date Analyzed: 10/5/2001 Bartch#: 0110A6K8 SUMMARY OF ANALYTICAL RESULTS Site: r 21 West Street, New York, NY I

SAMPLE # COLLECTED DESCRIPTION I LOCATION TIWlE(min) VOLUME(I) FIB/FIELD RESULTS(f/cc) LAB#

013 Ambient/ 5th Floor Corridor 120 1837.8 2/100 0,001 05-October A 6947

014 Ambient/ Sth Floor Corridor 120 1837.8 2/100 0.001 05-October A 6948

015 Ambient/ Lobby Next to Mail Room 120 1837.8 4/100 0,001 05-October A 6949

016 Ambient/ Lobby Gym 120 1837.8 3/100 0.001 05-October A 6950

017 Ambient/ Apt. 11C/ Hallway By Bathroom 120 1837.8 2/100 0.001 05-October A 6951

018 Ambient/ Apt. 11C/ Children Room 120 1837.8 4/100 0.QQ1 05-October A 6952

Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/100 Fields Positive Phase Contrast Microscopy (PCM) VOIDI = H.C.P. ( High Concentration of Particles) VOID2 = Overloaded Method of Sample Preparation and Analysis: All sampAs analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994 Instrumentation: Olympus PCM Model BH-2 with Walton-Beckett Graticule (tOOum held diameter) ijuiam Tvracnmwaia Laboratory Director Report Date: October 6, 2001 JLC is responsible for only the fiber counts within ths limitations of the method described as NiOSH 7400. Among other limitations, this method gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysis of these samples are limited in recovery to ths cost of analyzing samples, JLC accepts no other liability and the client agrees to seek no costs beyond the above. Page 5 of 7

05074 CITY_21MC100_011971017

NYC-WTC_000418409

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418409Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →