NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 85 pages

Chain-of-custody: 21 West Street air samples, Feb 2002

Machine-extracted title · confidence 33%

Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.

NYC-WTC_000418335–000418419
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document r»±z±H Z.'UnaEii

JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092 Project No,: IOP20890O2 Rose Associates Inc, ELAP Lab Code: 11029 Analyte: FIBERS 200 Madison Ave. Sth Floor NIOSH and AIHA Lab Code: 100273 Date Received: 10/15/01 NayvYofk, NY 10016 NVLAP Lab Code; 101953 Date Analysed;: 10/16/01 Batch#; 0110A741 SUMMARY OF ANALYTICAL RESULTS Site: 21 West Street, New York, NY

SAMPLE# COLLECTED DESCRIPTION I LOCATION TIMEtmin) VOLUMEdt FIB/FIELD RESULTS(f/cc| LAB#

019 Ambient/ 51h Floor/ In Room 5N/ At the Bedroom 90 13S5 6/100 0.002 13-Oqtober section Beside the Window A 7531

020 Ambient/ Sth Floor/ Corridor/ At the North Section 90 1385 4/100 Q.001 12-Oclober of the Corridor A 7532

021 Ambient/ in the Lobby/ Next to the Mailroom 90 1385 3/100 0.001 12-October A 7533

022 Ambient/ In the Lobby/ Next to the Gym 90 1385 4/100 0.001 1 Z-October A 7S34

023 Ambient/ At the North Section of the PH Corridor 90 1385 5/100 0.002 12-Octoher A 7535

024 Ambient/ At the South Section of the PH Room D 90 1385 4/100 0.001 12-October A 7536

Sample Analysis by: <LOD = Less than limit of detection which Is 5.5 Fibers/100 Fields VOID1 = H.C.P. ( High Concentration of Particles) Positive Phase Contrast Microscopy (PCM) VOtD2 = Overloaded Method of samolB Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994

Instrumentation: arnA A J T?uiam Macnniwala Olympus PCM Model BH-2 with Walton-Beckett Graticule (lOOun field diameter). Laboratory Director Report Date: October 16, 2001 JLC is responsible for only the fiber counts within the limitations of the method described as NiOSH 7400. Among other limitations, this meth gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of J LG's analyst these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no coats b the above Page 4 of 5

05067 CITY_21MC100_011971010

NYC-WTC_000418402

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418402Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →