NYC 9/11 Public Portal Document
• JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2089004
Rose Associates Inc. ELAP Lab Code: 11029 Analyte: FIBERS
200 Madison Ave. 5th Floor NIOSH and AIHA Lab Code: 100273 Date Received: 10/25/2001
New York, NY 10016 NVLAP Lab Code: 101953 Date Analyzed: 10/25/2001
Batch #: 0110A824
SUMMARY OF ANALYTICAL RESULTS
Site: 21 West Street, New York, NY
SAMPLE #
COLLECTED DESCRIPTION / LOCATION TIME(min) VOLUME(1) FIB/FIELD RESULTS(f/cc)
LAB #
001 Ambient/ PH Floor/ PH D in the North Section of 120 1846 4/100 0.001<LOD
24-October the Living Room
A 8304
002 Ambient/ PH Floor/ Hallway Between PH B and 120 1846 6/100 0.002
24-October PH C
A 8305
003 Ambient/ 27th Floor/ Rm 27B at the North 120 1846 5/100 0.001<LOD
24-October Section of the Living Room
A 8306
004 Ambient/ 27th Floor/ Hallway Between Apt. 27D 120 1846 4/100 0.001<LOD
24-October and 27 E
A 8307
005 Ambient/ 22nd Floor/ Apt. 221/ At the North 120 1846 3/100 <0.001<LOD
24-October Section of the Living Room
A 8308
006 Ambient/ 22nd Floor/ Hallway Between Apt 22G 120 1846 4/100 0.001<LOD
24-October and 22H
A 8309
Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/ 100 Fields
VOIDI = H.C.P. (High Concentration of Particles)
Positive Phase Contrast Microscopy (PCM)
VOID2 = Overloaded
Method of Sample Preparation and Analysis:
All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994
Instrumentation:
Gulam MachhDirect
wa a
Olympus PCM Model BH-2 with Walton-Beckett Graticule (100um field diameter).
Laboratory Director
Report Date: November 8, 2001
JLC Is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this metho
gives only an Index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysis
these samples are limited In recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs b(
the above.
Page 1 of 5
NYC-WTC 000094650
OCR can misread numbers and units. Confirm readings against the page image before using them.