Chain-of-custody: 21 West Street air samples, Feb 2002

Machine-extracted title · confidence 33%

Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.

NYC-WTC_000418335–000418419
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document • •Mf’M- -sjaj-V'.

JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: {212)420-8119 Fax: (212) 420-6092 Proj ect No.; 01-2089004 Rose Associates Inc. ELAP Lab Code; 11029 Analyte: FIBERS 200 Madison Ave, 5th Floor NIOSH and AIHA Lab Code: 100273 Date Received; 10/25/2001 New York, NY 10016 NVLAP Lab Code: 101953 Date Analyzed; 10/25/2001 Batch#: C11OA024 SUMMARY OF ANALYTICAL RESULTS Site: 21 IVesf Street, New York, NY

SAMPLE # coLLEC-reo DESCRIPTION I LOCATION TIMEtmint VOLUME(I) FIB/FIELD RESULTS{f/cc) LAB#

001 Ambient/ PH Floor/ PH D in the North Section of 120 1846 4/100 O.OOKLOD 24-OctDber the Living Room A 8304

002 Ambient/ PH Floor/ Hallway Between PH B and 120 1846 6/100 0.002 24-October PHC A 8305

003 Ambient/ 27th Floor/ Rm 27B at the North 120 1846 5/100 O.OOKLOD 24-OcfobGr Section of the Living Room A 0306

004 Ambient/ 27th Floor/ Hailway Between Apt, 27D 120 1846 4/100 O.OOKLOD 24-October and 27 E A 8307

005 Ambient/ 22nd Floor/ Apt. 22K/ At the North 120 1846 3/100 <O.OOKLOD 24-October Section of the Living Room A 8308

006 Ambient/ 22ncl Floor/ Hallway Between Apt 22G 120 1846 4/100 O.QQKLOD 24-October and 22H A 8309

Sample Analysis by: <LOD =Less than limit of detection which is 5.5 Fibers/100 Fields vol DI = H.C.P. ( High Concentration of Particles) Positive Phase Contrast Microscopy (PCM) VOID2 = Overloaded Method of Sam ole Preearafion and Analysis: AH samples analyzed In accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994

InsfrumejTtetion: Gulam Machhiwaia Olympus PCM Model BH-2 with Walton-Beckett Graticule (1 OOum field diameter). Laboratory Director Report Date: November 8, 2001 JLC is responsible for only the fiber counts within the limitations of ths method described as NIOSH 7400. Among other limitations, this metho gives only an Index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysii these samples are limited in recovery to the cost of analyzing samples. JLC accepts no cttier liability and the client agrees to seek no costs bi the above. Page 1 of 5

05057 CITY_21MC100_011971000

NYC-WTC_000418392

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418392Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →