NYC 9/11 Public Portal Document . ,. . U-. • . ...... —. .J.,,...—r. - .4 •. *7^ r-S-

FEB-28-2Q02 THU 11:22 AM CLOSINGS ® ROSE FAX NO. 212 21Q 6724 P. 41/42

I Rose Asaociates page 2 JLC Project'^ 01-2089 Bulk BLiiidina Materials Analysis and Procedure

Introduction Polarized light microscopy with dispersion staining fPLM-DS) is the moat efficient method for detecting ' asbestos in bulk samples. It is this method that ths JLC lab uses during bulk building material analyses,

Methodology A chain of custedy is kept for each sample to ensure proper handling and de'ivery to the JLC lab prior to analysis. To avoid any possible contamina^on, alt sample and slide preparation is carried out Ir a ventilated, HEPA-filter hood with continuous airflow. Sample analysis is performed using PLM-DS in aeoordanoe with th® USEPA . ’WAthoU for the Determination of Asbestos in Buik Building Materials,'' EPA W R 93 116, July 1993, and NYDOH-ELAP certification manual, ''Polarized Light Microscope Methods ter Identifying and Quantiieiting Asbostoa in Bulk Semples," ELAP 19S.1, October 1993.

Analytical Procedural All aampios are subject to preliminary visual stereemicrcscoplc examinatiori. Observation of hontiogfinfilfy, i fjper Wentiflcatlon, and sempquantitetion of oonstituents can be made at this point. Samples lacking unifurmity of composition and/or distribution of oomponont materials then undergo homogeniaation. Some f ndn-lrlable organlcelly bound (NOB) samples such as floor tiles and roofing materials may require additional ,' . steps IP dislOdgB problem matrices (te, ashing, exhactiuns. and TEM).

Jetentificaficuraf suspect fibara is mads by PLM analysis of subsamples. A microscope equipped with dual i pnlariiing filters enables us to observe specific optical characteristics of each sampie. Positive identification pf ^iabeste£i requires determination of the following optical properties; morphology, color and pleochroism, rOfrdctive indices, birefringence, extinction characteristics, and signs of elongatinn

Asti6»alqs quantitiatiori is perFormed by poini-counting procedure, q ctandard iaehnique in petrography for determSoing the relative areas occupied by separate minerals in rock. An ocular reticle superimposes a point or points over ths microscope's field of viev^. The number of points posliicned directly above each kind of partlds or fiber is recorded. A total of 400 points must be counted over at least sight different representative subsarbptes to complete analysis. V .1 Polarized Light Microscopy i JLC' uses an Olympus BHT-P Polarizing Microscope complete with polarizer, analyzer, port for wave ! ffitsrdation plate, 360 degree graduated rotating stage, substage condenser, lamp and lamp I ri a, eyepiece reticle, and 26 point Chalktey Point Array, Plane polarized light allows for the determination of refraction indices relative tn fipscific nrystaliographic orientations, Morphology and color can also be observed under plane polarized light. Obsarvation of particles or fibers while oriented between polarizing filters whose pflvilegod vibratten directions are perpendicular allows for determination of Isotropism/anistropism, fexlinction charscteirisftcs of anisotropic particles, and calculation of birefringence. A retardation plats may he placed In the polarized light path for verification of signs of elongation.

if’ Analytical Results Tfia "Summary of Analytical Results" roprosonts tho results of analysis, Positivo result® mean the sample fs asbestos or contains more than one percent asbestos by weight. Ths results are generally sufficient for identification and quantitation of major concentrations cf asbestes. HuwKvur it may be found that additional techniques may be necessary. Please be aware that PLM is not consislsniy reliable in ttetecting asbestos in floor coverings and similar NOB materials, Before the material can bs considered or treated as non asbasins ennteinina. conFIrmatioh musibs made by quantitative Transmission Electron Microscopy (TEM),

05040 CITY_21MC100_011970983

NYC-WTC_000418375

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418375Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →