NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 85 pages

Chain-of-custody: 21 West Street air samples, Feb 2002

Machine-extracted title · confidence 33%

Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.

NYC-WTC_000418335–000418419
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FEB~28-2002 TH’J 11 HO All CLOSINGS ROSE FAR NO. 212 210 S724 P. 21/42

Ro$e Associates Ino, JIG Project #01-2065002 f'l October 16,2001 1 page 2 Air Samp5iria Ah^vsb and Procedure

Entroductlon /Mr sampling is defined ss the process of measuring the filter content of a known volume of air ehlrsined on a filter msmbrane over a spsdfted period of time . Each asmpSe is cross-referenced by field designation and a JLG iab interna! code to ensure proper, consistent handling through a chain of custody. Sample preparation takes pteqe withhi an HEPA fiiter clean bench to avoid any posslhis contamination.

I Methedotegy Teat procedures for these aemptea cqnfarrr, to the National Inststote of Occupations! Safety and Health (NIOSH) stendards, Asr epmpilng was conducted at a level approximating the breathing i:one of persons anticipated to be present in the area during norma! operations. Samples collected should represent ths area's typical airborne fiber concentration. 1-. Aii Bampies v/ere collected an fully exposed 25 miilfmeter, 0,8 micrometer (pm) cellulose ester f nhambrane air sampiing cassettftA with onnduotive cov>fl

Analytical Procedures A section of the filter approximating iwenty-five percent of the total filter was removed and placed on a prs-cleanad microscope slide and then exposed to approximately 250 microliter (pi) of acetons . i Vspor A single 3,0 - 3,5 pl drop of triacetin was applied and a clean #1.5 cover slip was placed upon lh« filter. The prepared slide was then heated on a slide heater until cl&ily alluwed analysis to be conducted,

Analysis was sqcqmpiished utilizing a Phase Contrast Microscope in accordance with NIOSH 7400 method* counting rule "A.'*

Phase Contrast lUEicrosoopy JUC Environmentafs laboratory uses an Olympus BH-PC Phase Contrast Microscope, (PCM) equipped with a Walton-Beckett Graticule, Samples were analyzed by first dissolving the filter through a chemical process (described above) and Uien ouunlliig Uie fibers with PCM at 400x masnlf(cation, Phase contrast increases the light corstrset between the object and the background, thus enhancing the microscopiaVs ability to see fibers. Normally, 100 microscopic fields or 100 fibera are counted, whichever occurs first.

Analytical Results 3 he ’’Summary of Analytical Results" represents the results of ths analysis of the samples. The PCM limit of reliable quantification is less than 0,01 fitere/cubic centimeter (f/cc) of air If final teftfa do not meet these requirements, the entire work site must be re-ciaaned and re-tested. J,

05020 CITY_21MC100_0 11970963

NYC-WTC_000418355

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418355Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →