NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Staten Island asbestos air sampling, Oct 2001

Machine-extracted title · confidence 28%

NYC Emergency Response asbestos air results; PCM/ TEM readings across multiple PLOC sites.

NYC-WTC_000417617
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC Emergency Response Asbestos Air Sampling Results for Staten Island Landfill Sampling Date and Time: 10/12/01 1900 to 10/13/01 0600

PCM by NIOSH 7400 TEM { AHERA) Sampling Sampling Sample f/mm^ f/cc Structures {#) S/mm^ S~t/cc* Date Sample No. Location Volume Matrix O.S-Sp >5p

10/13/01 03132 P Loc # 1 702.1 Air <7.0 <0.004 0 0 <8.61 <0.0047 10/13/01 03133 P Loc # 2 701.6 Air <7.0 <0.004 0 0 <8.61 <0.0047 10/13/01 03134 P Loc # 3 701.5 Air <7.0 <0.004 0 0 <8.61 <0.0047 10/13/01 03135 P Loc # 4 694.6 Air <7.0 <0.004 0 0 <8.61 <0.0048 10/13/01 03136 P Loc # 5 691.6 Air 8.92 0.005 0 0 <8.61 <0.0048 10/13/01 03137 P Loc # 6 685.2 Air 10.83 0.006 0 0 <8.61 <0.0048 10/13/01 03138 P Loc # 7 687.8 Air <7.0 <0.004 0 0 <8.61 <0.0048 10/13/01 03139 P Loc # 8 686.2 Air <7.0 <0 004 0 0 <8.61 <0 0048 10/13/01 03140 S Loc # 9A 11 Air <7.0 <0.245 0 0 <7.75 <0.2713 10/13/01 03161 S Loc # 9B 720 Air <7.0 <0.004 0 0 <8.61 <0.0046 10/13/01 03162 S Loc # 9C 720 Air <7.0 <0.004 0 0 <8.61 <0.0046 10/13/01 03163 S Loc # 10 A 720 Air <7.0 <0 004 0 0 <8.61 <0 0046 10/13/01 03164 SLoc#10B 720 Air <7.0 <0.004 0 0 <8.61 <0.0046 10/13/01 03165 W Loc #11 660 Air 7.01 0.004 0 0 <7.75 <0.0045 10/13/01 03166 W Loc# 12 720 Air 21.66 0.012 0 0 <8.61 <0.0046 10/13/01 03167 B Loc# 13 696 Air <7.0 <0 004 0 0 <8.61 <0 0048 10/13/01 03168 B Loc# 14 694.3 Air <7.0 <0.004 0 0 <8.61 <0.0035 coc# 04627 ** Chrysotile; no other types of asbestos were detected.

NS: Not sampled AF/ANF: Asbestos fibers/Non asbestos fibers Sample volume is below recommended limit of the method: ‘Structure (S) roughly equivalent to fiber (f) NA: not analyzed due to overloading of particulates

NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/rnm^, voiume 1200 L, for 25 mm fiiter (TEM)

ERT: 10/14/01 9:50 AM

o H

S o O O Io o co co FK-10-13-01 o co co

NYC-WTC_000417617

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000417617Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000307486

NYC/ER air sampling results; PM/air concentrations reported for several logs; data table present.

Similar indexed content