NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 21 pages

Lab report, indoor air quality, 4 Wall Street, 2001

Machine-extracted title · confidence 40%

Final indoor air quality evaluation report for 4 Wall Street, Oct 2001.

NYC-WTC_000417388–000417408
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Oct-DE-Zaai 11:04 FroB-CLAYTONGGROUPQ + T-E24 P.OOe/OZl F-ZEl

/VClaytoii tKCtjf S6/Ivbcet

Carbon monoxide is a colorless, odorless gas pioduced-by the’incomplete oombustion of solid, liquid, and gaseous fuels. In the absence of indoor sources, indoor carbon monoxide concentrations are generally similar to outdoor concentrations. ASHRAE Standard 62-1999 recommends an upper limit for carbon tnonoxide of 9 ppm as an 8 hour average, and 35 ppm as a 1-hour average. The OSHA PEL for carbon monoxide exposure is 50 ppm as an 8-hour TWA.

Dry Bulb Temperatures

The outdoor range of air temperatures over the 3-day evaluation, as measured on Wall Street, was 71 to 75 °F. Dry-bulb temperatures measured within the building ranged from 67 to 78 “F. with one exception. The lemperature in the mechanical area of subgrade level E was 76 to 82 °F.

ASHRAE Standard 55-1992 recommends indoor summer-season temperature lower and upper limits for occupant comfort of approximately 73.0 "F and 79,0 “F (when indoor relative humidities are approximately 50 percent). As such, the temperature ranges measured within the building were within the ASHR.AE Standard 55-1992 upper and lower limits for comfort.

Relative Humidity

Indoor relative humidity rsinged from 42 to 57 percent, The outdoor relative humidity level over the 3-day evaluation ranged from 67 to 76 percent. Clayton regards the broad range of indoor relative humidity of 30 to 60 percent as the most acceptable for occupant comfort. As such, relative humidity levels measured within the building were determined to be within these acceptable ranges.

Indoor relative humidity levels above 60 percent can promote indoor microbial growth. Wintertime relative hurqidity levels in she 20 to 30 percent range are marginally acceptable, but may cause discomfort to sensitive individuals. Humidity below 20 percent is less acceptable because of the effect of dry air on both the mucous membranes and the .skin.

3.2 AIRBORNE FIBER CONCENTRATIONS

Clayton collected one area air sample for airborne fiber concentrations per floor evaluated. Generally, the air samples were collected in proximity to the main elevator lobby of each floor. Bankers Trust occupies floors 2 through 7, Mezzanine Two, and subgrade levels A und C- Sampling locations on these floors were determined by a Bankers Trust building engineer.

The .sampling and analysis protocol for the collection of area air samples for airborne libers was conducted in accordance with NIOSH Method 7400, A Rules, Samples were collected using 25-mininieier (mm) 0,8-micron (pm) mixed cellulose ester filters (MCEF) and high-volume air sampling pumps calibrated wiih a flowrate of approximately 13 liters per minute. A minimum volume of approximately 1,200 liters of air was collected for 4

04299 CITY_21MC100_008877509

NYC-WTC_000417394

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000417394Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000390450

Appendix A shows direct-reading environmental measurements; file references city project codes.

Similar indexed content

NYC-WTC_000390456

Appendix B lists analytical results for area air sampling of airborne fiber concentrations.

Similar indexed content

Compare copies and versions →