Chain-of-custody, 80 [name] environmental hazard reports, Feb 2002

Machine-extracted title · confidence 42%

Copy of environmental hazard assessment reports from JLC Environmental Consultants.

NYC-WTC_000417141–000417245
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Hiaiusia?’-' • ihUi±A i:

JLC ’NVIRONMENTAL CONSULTANT*" NC. 200 Pc . ivenue SouUi, Suits 1001, New York, New Yu,. - ,0003 Phone: (212)420-8119 Fax: (212) 420-6092 WSA Management Project No, 01-2171 ELAP Lab Code: 11029 Analyte: LEAD 100 Ring Road West NIOSH and AIHA Lab Code: 100273 Date Collected: lOCBOt Garden City, NY 11530 NVLAP Lab Cipde; 101953 Date Received: 10/30/01 Date Analyzed: 10/30/01 Site: 80 John Street, New York, NY Lab Batch#: 011OL2167

SUMMARY OF ANALYTICAL RESULTS - AIR

Sample # Lab# Description/ Location Volume (liter) Results (ug/m3) Client's Sample #

1 Ambient/ Apartment 17C/ South East 240 <16,7 16443 Bedroom/ On East Side 01

2 Ambient/Apartment 170/ North West 240 <16,7 18444 Room/On North Side 02 3 Ambient/11th Floor/ Hailway Elevator/ 240 <16,7 18445 Hailway on South Side of Hallway 03

4 Ambient/11th Floor/ Hallway Elevator/ 240 <16,7 18446 Hallway on North Side of Hallway 04 5 Ambient/11th Floor/ Apartment 11B/ West 240 . <16,7 18447 Side Bedroom/ North West Near Closet 05

Samole Analysis bv: Alomis Absorplion Epectromsiry (AAS) wHti an air-aoelyfene burner head (Flame) and background correel ion (AAS-Flanie).

.MetbcLd of Sample .Preparation and Analysis CoHeoted By: Mohammed Khan All Samples were prepared and analyzed in accordance with NIOSH Method 7082, February IS, 1984, Analyzed By: Tamara Metelkina

Gulam Machhiwaia Laboratory Director

Minimum Da election Limit = <4.0 ug/m3 OSHA Permissible Exposure Limit (PEL) for General Industry is 50 ug/m3.

Page 1 of 2

10522 CITY_21MC100_008875472

NYC-WTC_000417219

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000417219Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →