DEC. 3.2001 12:06PM JLC ENVIRONMENTAL NO.157 P.5 JLC F VIRONMENTAL CONSULTANTS. 200 Par., .,/enue South. Suite 1001, New York, New York ..,003 Phone:(212)420-8119 Fax (212)420-6092 WSA Management Project No. 012222 ELAP Lab Code: 11029 Analyte: LEAD 100 Ring Road West NIOSH and AIHA Lab Code: 100273 Date Collected: •11/30/01 Garden City, NY 11530 NVLAP Lab Code: 101953 Date Received: 11/30/01 Date Analyzed: 12/3/01 Site: -p11 New York, NY Lab Batch #: 0111 L2254

SUMMARY OF ANALYTICAL RESULTS - AIR

Sample # Lab # Description/ Location Volume (Miter) Results (ug/m3) Client's Sample #

1 Ambient/ Outside/ Apartment_.Pu North 240 <16.6 19339 Bedroom/ With Door on Right 01 2 Ambient/ South East Bedroom/ gatr_ance 240 <16.6 19340 Door on Right/ Apartment P11 02 3 Ambient! Corridor/ 5th Floor/ South End of 240 <16.6 19341 the Corridor with Wall 03 ` ' •""

4 Ambient/ Corridor/ 5th Floor/ North End of 240 <16.6 19342 the Corridor with Wall 04 5 Ambient/ 7th Floor/ Apartment PII North 240 <16.6 19343 Bedroom/ Entrance Door on Right 05

Sample Analysis by: Atomis A►eorptbn Spectrometry (AAS) with an alr.acetylane burner head (Flame) and badcground correction (MS-Flame). Method of Sample Preparation and Analysis Collected By: Mohammad Mohammed Khan All Samples were prepared and analyzed in accordance with NIOSH Method 7082, February 15, 1984. Analyzed By: Tamara Kh na

Gulam Machhuwala Laboratory Director

Minimum Decbeetlon Limit = <4.0 ug/m3 OSHA Permissible Exposure Limit(PEL)for General Industry Is 50 ug/m3.

Page 1 of 2

NYC-WTC 000108603

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000108603Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →