Washdown request for AMEX Building, FEMA funds

Machine-extracted title · confidence 40%

Request for FEMA funding review to finance cleaning of AMEX Building (200 Vesey).

NYC-WTC_000416719–000416737
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

GPS Envit'onmenial Consultants, Inc.

The east side of the facility, where windows were broken and gross matsnul entered w'as separated from the rest of tire floor by polyethylene isolation barriers. Negative air machine were installed to assist in controlling fiber release from the east side. Cleanup work on both the east and west side of the facility was performed by a licensed Asbestos Abatement Contractor utilizing certified asbestos handlers and supervisors. GPS Environmental, a licensed Asbestos Consulting Jimi, performed asbestos air sampling. Sampling w'us performed during each phase of the cleanup operation and at the conclusion of each phase post/final asbestos air sampling was performed.

Pinnacle Environmental Corporation, a NYS Licensed Asbestos Abatement Company, located at 64-54 Maurice Avenue, Maspeth, New York, performed alt Phase 1 abatement activities. Pinnacle personnel included only New York State Department of Labor (NYSDOL) and NYCDEP certified supervisors and asbestos handlers. BMS Catastrophe, a disaster recovery firm, performed phase IT cleaning operations under the review- of GPS Environmental. The procedures for each cleaning phase is briefly outlined below:

Phase I was conducted so that an acceptable environment could be obtained for limited access of essential personnel to seal open windows, assess damage to equipment, inventory' items to be disposed of, etc. Phase one was conducted as an asbestos abatement project on the east side of the building where gi^oss debris entered the facility through broken windows, GPS was the “Third Party” Asbestos Air Sampling Consultant for this aspect of the project as required by NYC and NYS asbestos regulations. On the west side of the facility and where only dust was present asbestos abatement personnel cleaned using asbestos specific procedures.

Phase II involved a fine, detailed cleaning of the facility from the Penthouse to level C3. EMS Catastrophe, a worldwide disaster recovery firm, utilizing asbestos abatement personnel performed the fine cleaning. BMS was employed directly by Merrill and managed under a management agreement by GPS Environmental.

Phase III Procedure Overview - The ventilation ductwork was in.spected by a trained HVAC specialist employed by Tri Dim Corporation on October 19, 2001, Areas detemnined to be contaminated were cleaned by a certified duct-cleaning firm, Kasco, Following cleaning of the ductwork, all compartment units were activated after filters were placed in all supply grilles by BMS personnel. GPS conducted continuous asbestos air sampling for each floor for a 24-48 hour period to ensure that airborne fiber concentration levels were not exceeded due to missed contaminates within the local ductwork. Once the fresh air intake ducts were cleaned and a new filtration system in place, both the upper and lower fresh air fans were turned on. As a measure to ensure a safe environment for all occupants, GPS conducted continuous asbestos air sampling for each floor as the compartment units and fresh air fans ran for a 24- 48 hour period.

Msfrill Lynch, World Linancial Center. South Tower, ll.-y Hherty Street, New York, NY Page 3

11534

CITY_DEP_HILLMAN_SUBP_000005158

NYC-WTC_0004 16732

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000416732Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →