ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/02/01

ASBESTOS FIB-ER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) wich h'iber identitication by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, ERA Federal Register (40 CFR, Fart 763), vol. 52, No. 210, October 30, I9b7

Sample Identification Analysis Parameters

Project/Site; P.5. 234M, 292 Greenwich St., NY., NY TEM Sample No.: 5592 59914 Entire School Date Received: 10/02/01 Grid Openings Analyzed:__4

Project Sample No.: PS234M-BS-10/2-20 Average Grid Opening: 106.00 um

Arr Volume: 1320 liters Total Area Analyzed: Q.Q450 mm2

Filter Type: MCE 25 mm diam., Pore Size: Q.45 um Analytical Sensitivity: 22.2 s/mm2 Effective Area :385[rnn2 0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/nim2 Struct/cc nam/ni3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 O.QOGG 0

Total asbestos (includes ambiguous structures) 0 0 3.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 3,0 0 - 0000 N/A No Identification 0 0 0 0 0 0 3.0 0.0000 N/A

Totals (All Structures) 0 13 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d, (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_011771759 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000411588

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000411588Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →