NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis with SAED/EDS, PS 234M

Machine-extracted title · confidence 42%

Asbestos fiber TEM with SAED/EDS for PS 234M, Oct 2, 2001.

NYC-WTC_000411573
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/C2/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diftracticn (SAEh) and Energy-ni .Bpersive X-RAY Spectroscopy (ZDS) Method: AHERA Final Rule, E?A Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 19H7

Sampla Identification /Analysis Parameters

Project/Site. P.S. 234M, 292 Greenwich St., NY, NY TEM Sample No.: 5592 59899

Entire School Date Received; 13/02/01 Grid Opening’s Analyzed:__ 4

Project Sample No. : PS234M-ES-lQ/'2-04 Average Grid Cpening’: 106 .PC un

Air Volume; 1310 liters Total Area Analysed:0^0450 mm2

Filter Type: MCE 25 mm diam., Pore Size: Q.45 um Analytical Sensitivity:22;2 s/mm2

Effective Area; 385 mm2 C . 0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters SC^tict;Struc^ > = 5um Struct/mm2 Struct/cc ncjm/TTij

Chrysotile Asbestos 0 0 3 0 0 0 0.0 3.000C 0

Amphibole Asbestos 0 0 0 0 0 0 9.0 0.000c 0

Ambiguous 0 0 0 0 0 0 0.0 3.0000 0

Total asbestos (includes ambiguous structures) 0 0 3.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 3.0 0.OOGO N/A No Identification 0 0 0 0 0 0 3.0 0.0000 N/A

Totals (All Structures) 0 0 3.0 O.OCOO N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A, Gorycki, Ph.D. Director of Electron Microscopy

CONFIDENTIAL, CITY_21MC100_011771743 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000411573

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000411573Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →