NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
I 1700 Elm Street - Suite 200
I! Minneapolis. MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Teh 612-607-1700
612- 507-6444
/ Client - ATC ASSOCIATES
Client's Sample ID ATC-0905-M833-DX-1
Lab Sample ID 103841292
Filename F21011B_14
Injected By BAL
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 09/05/2002
ICALDate 10/01/2002 Received 09/10/2002
CCal Filename(s) F21011B_02&F21011B_18 Extracted 10/06/2002
Method Blank ID BLANK-2262 Analyzed 10/12/2002 07:34
Native Cone EMPC LRL Internal ng'S Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3.7,8-TCDF ND 0.0023 A 2,3,7,8-TCDF-13C 2.00 69
Total TCDF ND 0.0020 2,3,7,8-TCDO-13C 2.00 66
1,2,3,7,8-PeCDF-13C 2.00 87
2,3,7,8-TCDD ND 0.0034 A 2,3,4,7,8-PeCDF-13C 2.00 93
Total TCDD 0.015 0.0020 1,2,3,7,8-PeCDD-13C 2.00 85
1,2,3,4,7.8-HxCDF-13C 2.00 94
1,2,3,7,8-PeCDF ND 0.0100 1,2.3,6,7,8-HxCDF-13C 2.00 100
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxGDF-13C 2.00 104
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 101
1,2,3,4,7,8-HxCDD-13C 2.00 85
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 91
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 89
1,2,3,4,7,8,9-HpCDF-13C 2.00 92
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 85
t,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 85
2,3,4,B,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2.3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2.3,7,8,9-HxCDD-13C 2.00 NA
1,2,3.4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37Cl4 0.20 65
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2.3,4,6.7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 'Equivalence: 0.00032 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.017 0.0100 J
Total HpCDD 0.031 0.0100 J
OCDF 0.021 0.0200 J
OCDD 0.130 0.0200
LRL = Lower Reporting Limit
Conc= Concentration (Totals include 2.3,7,g-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NO = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 1062384
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,,
without the written consent of Pace Ahaiytical Services, Inc.
CONFIDENTIAL, CITY_2IMCI00_011771486
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000411430