NYC-WTC_000411213
ATC indoor air quality measurements at PS 89M; June 21, 2002 report.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗BOE requested IAQ measurements at PS 89M to evaluate school building air quality.
NYC-WTC_000411226–000411229OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan June 25, 2002 Indoor Air Quality Assessment Page 3 P. S. 89M ATC Project No. 15-19125-0297
Real-Time Environmental Measurements
ATC collected eighty (80) sets of real-time environmental measurements consisting of seventy (70) from inside the school building and ten (10) from outdoors. All five floors of the school building were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded at approximately 10:51 A.M.
Temperature
Indoor dry bulb temperature measurements ranged from 72.1 °F to .78.1 °F. Thirteen (13) of the indoor measurements for temperature were below the range of 73 to 79°F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the summer season. The outdoor temperature measurements ranged from 78.3 °F to 79.7 °F.
Relative Humidity
The relative humidity indoors ranged from 46.1 to 53.6 percent. All of the indoor measurements for relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 55.3 to 55.8 percent. w <
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 526 ppm to 1242 ppm. All of the indoor 7 measurements for GO2 were within the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 571 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1271 ppm (background level + 700 ppm). Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of CO2 indoors is occupant respiration. The school building was occupied during ATC’s assessment.
Carbon Monoxide Concentration
Carbon- monoxide concentrations indoors were 1 ppm for all readings. These concentrations were within the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentration were also 1 ppm for all collected readings.
Respirable Particulates (PM2,j) i
Respirable particulate concentrations* indoors ranged between 16 pg/m^ to 64 pg/m^. The average PM2.5 concentration for the entire school building was approximately 27 pghn-. None of the indoor measurements were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Five (5) of the indoor measurements were above the USEPA recommended concentration of 40 pg/m^ for'
CONFIDENTIAL, CITY_21MC100_003488664 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000411228
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000411213
ATC indoor air quality measurements at PS 89M; June 21, 2002 report.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370089
ATC IAQ measurements conducted June 20, 2002 at PS 89M for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370113
ATC IAQ measurements collected June 24, 2002 at PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370101
ATC IAQ report for PS 89M dated June 21, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313952
ATC report of IAQ measurements at P.S. 89M, June 24, 2002, requested by NYC BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370061
ATC reports indoor air quality measurements taken June 17, 2002 at PS 89M for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313646
ATC IAQ measurements at PS 89M for May 13-14, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313893
ATC IAQ measurements collected June 18, 2002 at PS 89M per BOE request.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369326
IAQ measurements collected June 20, 2002 for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370077
ATC IAQ measurements conducted June 19, 2002 at PS 89M for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369350
June 2002 IAQ measurements at PS 89M requested by BOE to evaluate air quality.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313940
ATC IAQ measurements collected June 21, 2002 for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000411213
ATC indoor air quality measurements at PS 89M; June 21, 2002 report.
Similar indexed content
NYC-WTC_000370089
ATC IAQ measurements conducted June 20, 2002 at PS 89M for BOE.
Similar indexed content
NYC-WTC_000370113
ATC IAQ measurements collected June 24, 2002 at PS 89M.
Similar indexed content
NYC-WTC_000370101
ATC IAQ report for PS 89M dated June 21, 2002.
Similar indexed content
NYC-WTC_000313952
ATC report of IAQ measurements at P.S. 89M, June 24, 2002, requested by NYC BOE.
Similar indexed content