NYC-WTC_000380186
TEM asbestos analysis results for exterior/interior air at New Stuyvesant High School, Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM analysis documentation for exterior/interior samples at New Stuyvesant HS, Feb 2002.
NYC-WTC_000410879–000410881OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
B ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212) 353-8280 Fax;(212)353-8306
Attn: Mr. Bernard Orlan Received: 2/23/02 5:30:00 PM N.Y.C. Board of Education ATC Group#: 6801 ■ 28-11 Queens Plaza North Analysis Date: 2/24/02 Long Island City, NY 11101 Fax: (212) 475-4122- Phone: (212) 477-8941 Project: New. Stuyvesant H. S. , 345 Chambers St.,.NY ■ NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) . .............. Andlyticdl' Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample yotuine Analyzed Asb Type(s) 0.5ft-5 5fi (S/cc) (S/mm^) (S/cc) Notes ---YA
1 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6801 -I -a 2 1936.00 0.0450 0 None Detected ' 0 0 0.0044 <22.24. <0.0044 6801 -2
3 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6801 -3
4 1928.00 0.0450 0 None Detected 0 . 0 0.0044 <22.24 <0.0044 6801 -4
5 ■ 1936.00 0.0450 0 None Detected O' 0 0.0044 <22.24 < 0.0044 680.1 -5
1936.00 0.0450"' ’ 0 None Detected ' 0*' 0 0.0044 <22.24 ' <010044 6801 -6
7 1936.00 0.0450 0 NoneDetected 0, 0 ■' 0.0044’ .<22.24 <0.0044 • 680.1.-7
8 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6801 -8
ROMAN PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
Analyzed by: Approved by: z
Disclaimer; The laboratory is not responsible for data reported in stmcturesicc. which is dependent on volume collected by nonTaboratory personnel. This lab is only responsible for data repotted in structures/mm*. This report may not be reproduced, except in full, without written approval by. ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Govemrnent. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and. laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLMrrEM.#10l167-0, NY State ELAP #10879
CONFIDENTIAL, CITY_21MC1OO_OO3389142 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000410879
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000380186
TEM asbestos analysis results for exterior/interior air at New Stuyvesant High School, Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273481
TEM asbestos analysis results for air samples collected at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380925
TEM asbestos analysis for Stuyvesant High School AHERA project documentation.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349388
TEM asbestos analysis results for New Stuyvesant High School samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262652
Asbestos TEM analysis of air samples at New Stuyvesant H.S. using AHERA method; result details included.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300336
TEM asbestos analysis results for exterior and interior air at New Stuyvesant High School, May 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299086
Chain of custody and air monitoring data for TEM analyses at building site.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349899
Asbestos analysis report for exterior/interior building areas at New Stuyvesant High School, June 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349472
TEM asbestos analysis with concentrations for New Stuyvesant project.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299281
Chain-of-custody and TEM analysis summary for air samples from New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300312
Chain-of-custody form for air monitoring data linked to TEM asbestos analysis at DOE project.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000192041
Laboratory report detailing asbestos fiber analysis via TEM for a high school building exterior and interior.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis results for exterior/interior air at New Stuyvesant High School, Feb 2002.
Similar indexed content
TEM asbestos analysis results for air samples collected at New Stuyvesant High School.
Similar indexed content
NYC-WTC_000380925
TEM asbestos analysis for Stuyvesant High School AHERA project documentation.
Similar indexed content
NYC-WTC_000349388
TEM asbestos analysis results for New Stuyvesant High School samples.
Similar indexed content
Asbestos TEM analysis of air samples at New Stuyvesant H.S. using AHERA method; result details included.
Similar indexed content