NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Limited lead-in-dust report, HVAC rooms, Stuyvesant HS, 2002

Machine-extracted title · confidence 63%

Dust sampling report for HVAC systems at Stuyvesant High School; client and date shown.

NYC-WTC_000410175–000410177
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sampling Methodology

ATC provided all laboratory analytical services in support of this inspection, ATC is certified by the New York State Department of Health’s Environmental Laboratory Accreditation Program to perform lead and related analyses of environmental samples (Laboratoiy ID Number: 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method number SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

The samples were obtained by gently wiping a measured surface area with non-alcohol moistened towelettes, ATC’s representative wore disposable gloves; new gloves were worn with each new sample collected, and special care was taken to avoid contamination of the towelette and collection vial, Samples were then placed into 50ml plastic vials and immediately sealed. The chain of custody form was completed documenting the exact locations and measurements of the areas sampled.

Results of Dust Wipe Sampling

A total of fifteen (15) dust wipe samples were collected fi-om the above referenced locations. Laboratory analysis indicated that one (1) of the of the fifteen (15) samples collected from HVAC units was above the guideline level of 250 ug/ft* for window sills. Laboratory analysis also indicated that six (6) of the fifteen samples were above the guideline level 40 pg/ft’ for floors. The remaining eight (8) samples were below 40 pg/fV. The laboratoiy report and chain of custody forms for the samples collected are included in the Appendix of this report.

Limitations of dust wipe sampling

Lead wipe sampling was conducted at NYC-BOE request. The results of this report are applicable for the time the testing was performed. ATC makes no representations or warranties concerning the standards and specifications provided in the EPA and'or HUD Guidelines related to lead wipe sampling and interpretation of these sample results.

It is our pleasure to provide these services to New York City Board of Education. Should you have any questions regarding these sample results, please do not hesitate to contact me at (212) 353-8280 extension #211.

Sincerely, ATC Associates, Ina

Senior Project Manager

Stuyvesant US (M477) (Sactc * ItDCIAT INC May 2, 2002

CONFIDENTIAL, CITY_2IMC100_003388275 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000410177

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000410177Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →