Sampling Methodology

ATC provided all laboratory analytical services in support of this inspection. ATC is certified by the New York State Department of Health’s Environmental Laboratory Accreditation Program to perform lead and related analyses of environmental samples (Laboratory ID Number: 10879). The laboratory utilizes the United States Environmental Protection Agency analysis method number SW846-7420 and the National Institute of Occupational Safety and Health method number 7082M.

The samples were obtained by gently wiping a measured surface area with non-alcohol moistened towelettes. ATC’s representative wore disposable gloves; new gloves were worn with each new sample collected, and special care was taken to avoid contamination of the towelette and collection vial. Samples were then placed into 50ml plastic vials and immediately sealed. The chain of custody form was completed documenting the exact locations and measurements of the areas sampled.

Results of Dust Wipe Sampling

A total of eighteen (18) dust wipe samples were collected fi-om the above referenced locations. Laboratoiy analysis indicated that four (4) of the of the eighteen (18) samples collected from HVAC units were above the guideline level of 250 pg/fF for window sills. Laboratory analysis also indicated that ten (10) of the eighteen samples were above the guideline level 40 pg/fF for floors but below 250 pg/tf. The remaining four (4) samples were below 40 pg/fV. The laboratory report and chain of custody forms for the samples collected are included in the Appendix of this report.

Limitations of dust wipe sampling

Lead wipe sampling was conducted at NYC-BOE request. The results of this report are applicable for the time the testing was performed. ATC makes no representations or warranties concerning the standards and specifications provided in the ERA and/or HUD Guidelines related to lead wipe sampling and interpretation of these sample results.

It is our pleasure to provide these services to New York City Board of Education. Should you have any questions regarding these sample results, please do not hesitate to contact me at (212) 353-8280 extension #211.

Sincerely, ATCAssociates, Inc.

CX'iannis Efstathiou Senior Project Manager

1S306X May 2. 2002

CONFIDENTIAL, CITY_2IMCl00_003388302 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000229804

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000229804Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000178714

Report prepared by ATC Associates documenting limited lead-in-dust wipe sampling conducted at P.S. 150M in May 2002.

Similar indexed content

Compare copies and versions →