NYC 9/11 Public Portal Document
Scope of Work
A rC .Assccialcs. Inc. (ATC) was retained by New York City Board of Education (NYC-
BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were
collected foni areas recommended by the Parents Association consultant representative
Mr. Tom Eusillo of ENVIRON Corp, and approved by NYC- BOE and as specified in the
revised sampling protocol for the school. These areas are the following:
• Oi tside the Building., Small Playground Surfaces Three (3) samples
• Ottside the Building, by the Main Entrance - Three (31 samples
• Ortside the Building, Large Playground Surfaces - Five (5) samples
• L' Floor Hallway - One (1) sample
• Cafeteria - One (1) sample
• Auditorium - One (1) Sample
• Gy mnasi um - One {1) sample
• Throughout 2"'* floor - Seven (7) samples
• Throughout 3''‘ floor - Six (6) samples
• Throughout L' floor Five (5) samples
The purpese of the dust wipe sampling is to determine if dust in the school contains lead.
ATC will be repeating this sampling preferably every Saturday as per the
recommendation of ENVIRON Cinp. and after the approval of NYC-BOE. This is the
2A'' consecutive week dust samples were collected from P.S. 234M to be analyzed for
lead content after the sampling protocol is approved.
AFC’s representative Mr. Chacko Mathew visited P.S. 234M located at 292 Greenwich
Street, New York, NY on June 22, 2002. Dust wipes to be analyzed for lead content w ere
collected from the aforementioned areas indicated by ENVIRON and as specified by the
New York City Boa::d of Education Environmental Health & Safety Unit and in
accordance with HUD protocols.
LEAD-IN-DUST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173.14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection Agency (EPA) have established
acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels). As stated in the Code, final clearance
after abatement has taken place is achieved when dust wipe samples indicate lead levels
below those listed below:
For Windowsills: 250 ug tt
For Floom: 40 pg/fl"
For Exteror Concrete or Rough Surfaces: 800 pg/ft’
.C .S' 234M
CFATC June 24 201)2
CONFIDENTIAL, CITY_2 IMCl 0 0_Ci 018 9 7 8 3 9
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000409979
OCR can misread numbers and units. Confirm readings against the page image before using them.