NYC response, asbestos air sampling, Staten Island

Machine-extracted title · confidence 42%

Asbestos air sampling results for Staten Island area; PCM and TEM results shown.

NYC-WTC_000409820
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z z ■<

o o NYC Response co § Asbestos Air Sampling Results for Staten Island Landfill Sampling Date and Times: 11/01/01 1524 to 11/02/02 0050 '2 o o Sampling Sampling Sample PCM by N OSH 7400 _________ TEM AHERA) Structures (#) “0 c CT o' Date Sample No. Location Volume* Matrix f/mm’ f/cc 0.5p-5m sp S/mm^ S-f/cc** o "0 co 11/01/01 LF00127 P-1 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 o 00 11/01/01 LF00128 P-2 720 /Mr <7.0 <0.004 0 0 <8.75 <0.0047 a. CD KJ o P-3 720 Air <7.0 <0.004 0 0 <8.75 .210047 11/01/01 T LF00130 I P-4 720 Air <7.0 <0.004 0 8.75 0.0047 O 1... o P-5 720 Air <7.0 <0.004 0 8.75 0.0047 o c 11/01/01 LF00132 P-6 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 3 11/01/01 LF00133 P-7 720 Air <7.0 <0.004 0 0 <8.75 2^^0047 CD G 11/01/01 LF00134 P-8 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 W 11/01/01 LF00135 S-9A 0 Air R R R R R R G to 11/01/01 LF00136 S-9B 320 Air <7.0 <0.008 0 0 <7.87 G S-10A 720 Air <7.0 <0.004 0 0 <8.75 M O 11/01/01 LF00138 S-10B 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 H 11/01/01 LF00139 W-11 678 Air ~NA^ ~N^ 0 8.75 0.0050 H O 11/01/01 LF00140 W-12A 684.9 Air 26.75 0.015 r- 0 8.75 11/01/01 LF00141 W-12B 503 Air <7.0 <0.005 0 0 <7.87 <0.0060 3 11/01/01 LF00142 B-13 0 Air R R R R R R 3 11/01/01 B-14 Air O LF00143 720 <7.0 <0.004 1*** 0 8.75 0.0047 H 11/01/01 LF00144 T-15 681 Air 19.11 0.011 0 0 <8.75 <0.0049 M O O 11/01/01 LF00145 T-16 720 Air 11.46 0.006 0 0 <8.75 <0.0047 H O 3 11/01/01 LF00146 Lot Blank 0 Air <7.0 n/a na<^’ “na®" NA<®' < M 3 11/01/01 LF00147 Trip Blank 0 Air <7.0 n/a NA<‘' “na®" NA<^> a COC No. n/a o M 3 a H Key: M * Sample volume (liters) is below recommended limit for the TEM method; volume is based on pump reading > ** Structure (S) is roughly equivalent to fiber (f) 3 Chrysotile O **** Actinolite to NA - Not analyzed due to overloading of particulates NA'^>- Not analyzed for TEM w n/a - Not applicable M R - Sample rejected due to no sample volume 3 H NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/1 S«4 to Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) o o Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM). 70 S/mm?, volume 1200 L, for 25 mm filter (TEM) co O

H

KJ

o o o I o rK-11 -01-01 pmrevFinai RST: 11/7/2001 o

co co to

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000409820Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →