104 east 25th Street New York. New York 10010 www.atc-enviro com 212.353.8280 Fax 212.353.830a

September 26, 2001 ALC Environuantul -L- W. 30ch street - c J YCi- . Ls . Attn; Mr. .

Re: Report cf TEM Ajiilysis Dear Mr.

Foalowing are the results of fraitsmicaion electron microscopy (TEM) ana..vsis of eleven PCM air spitpies from our Group No. 5556: Clienc Project Name; 345 and 355 Southend Avenue Location: Hallways and Apartments, Buildings 100 and 200 Samples received in TEM Lab: 09/26/01

These results will confirm and document the data transmitted to you today. The analyses were performed in strict conformance with the methodology of the NIOSH method 7402, Issue 2, August 15, 1994. Forty grid openings from each of the samples were examined at relatively low magnifications (approximately l.OOOX and 10,000X) for structures greater than Sum in length and widths between 0.25um and 3uia, and having a length-to-width ratio greater than 3:1. These structures would be large enough to be observed by PCM analysis. Asbestos and non-asbestos structures were detected in the samples in the following proportions:

sample chrysotile gypsum cellulose fiber F/CC as number glass Asbestos

3 0.0% 93.8% 0.0% 6.2% 0.0 4 22.2% 77.8% 0.0% 0.0% 0.005 5 0.0% 76.9% 0.0% 23.1% 0.0 6 0.0% 55.0% 0.0% 45.0% 0.0 a 0.0% 76.2% 9.5% 14.3% 0.0 13 0.0% 77.3% 9.1% 13.6% 0.0 14 0.0% 100.0% 0.0% 0.0% 0.0 17 0.0% 100.0% 0.0% 0.0% 0.0 18 3.6% 68.7% 0.0% 27.7% 0.001 19 0.0% 66.7% 0.0% 33.3% 0.0 20 0.0% 42.0% 0.0% 58.0% 0.0

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000000016

NYC-WTC_0004091 11

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000409111Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342650

Lab report of TEM analysis for PCM air samples; Building project dated Sept 2001.

Similar indexed content

Compare copies and versions →