NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Lab report: PCM air sample results, 06/21/02

Machine-extracted title · confidence 35%

Lab results for PCM air sample collected 06/21/02, Testwell, Hilton, NYC.

NYC-WTC_000408854
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. Environmental Laboratory NYS Eb^P #11142

47 Hudson Street, Ossining, New York 10562 NVLAP 3 200033<1 AiHA 3 100147

f^CM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 06/21/02 Date Rec'd (lab): 06/24/02 Project #: MBO-025AB Analysis Date: 06/24/02 Analyst: M. Stein Sample Location: The Millenium Hilton 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York

Field Technician: B. Gitman

Sample #: Sample Location: Sampie Type 02PCM # Volume Concentration f/cc

731 Personal Decon During 18036 1200 <0.0023

732 Waste Decon During 18037 1200 0.0027

733 3rd Floor inside airlock During 18038 1200 0.0029

734 3rd Floor outside airlock During 18039 1200 <0.0023

735 23th floor inside air lock During 18040 1200 0.0055

736 23th floor outside air lock During 18041 1200 0.0049

737 24th floor inside air lock During 18042 1200 0.0041

738 24th floor outside air lock During 18043 1200 <0.0029

739 25th floor inside air lock During 18044 1200 0.0067

740 25th floor outside air lock During 18045 1200 0.0031

741 Personal Decon During 18046 1350 0.0027

742 Waste Decon During 18047 1350 0.0044

■ Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. Laboratory QC data available upon request. **** The laboratory has no control over air sampling collection. Reports are the confidential property cf our clients. This certificate of analysis/repcn shall not be used by the client to claim product encorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproducec except in full. without the written approval of Testwell Laboratories, Inc. -7

Deborah McCatl - Laboratory Director

CITY_21MC100_011963057

NYC-WTC_000408854

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000408854Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records