Lab report: PCM air sample results, 06/19/02

Machine-extracted title · confidence 35%

Lab results for PCM air sample collected 06/19/02, Testwell, Hilton, NYC.

NYC-WTC_000408846–000408849
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. Envii’onmental Laboratory NYS ELAP #11142

47 Hudson Street, Ossining, New York 10562 NVLAP # 20008341 AIHAS 100147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 06/19/02 Date Rec'd (lab): 06/20/02 Project #: MBO-025AB Analysis Date: 06/20/02 Analyst: D. Agrest Sample Location: The Millenium Hilton 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York

Field Technician: B. Gitman

Sample #: Sample Location: Sample Type 02PCM # Volume Concentration f/cc

699 26th Floor inside airlock During 17399 1250 <0.0022

700 26th floor freight elevator lobby During 17400 1250 <0.0022

701 27th Floor inside airlock During 17401 1250 0.0024

702 27th floor freight elevator lobby During 17402 1250 0.0075

703 28th Floor inside airlock During 17403 1250 0.0182

704 28th floor freight elevator lobby During 17404 1250 0.0067

705 3rd Floor inside airlock During 17405 1150 <0.0023

706 3rd floor freight elevator lobby During 17406 1150 <0.0023

707 Field Blank During 17407 N/A N/A

708 Field Blank During 17408 N/A N/A

* Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ” Sample information is provided by the client & presented as stated. *'* Laboratory QC data available uoon request. **” The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories, Inc.

Deborah McCah - Laboratory Director

CITY_21MC100_011963051

NYC-WTC_000408848

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000408848Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →