NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

Lab report: PCM air sample results, 2002

Machine-extracted title · confidence 35%

Laboratory results for PCM air sample collected 05/31/02, Testwell Laboratories, WTC area.

NYC-WTC_000408786–000408791
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. Environmental Laboratory NYS i 11142

47 Hudson Street, Ossining, New York 10562 NVVAP - 200083-0 AIHA ; 100147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/31/02 Date Rec’d (lab): 06/03/02 Project #: MBO-025AB Analysis Date: 06/03/02 Analyst: 4. Soko/ Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

Sample Concentration Sample #: Sample Location: 02PCM # Volume Type f/cc

Outside Work Area Clean Room or 391 During 15337 1200 <0.0023 Remote Personal Decon Outside Work Area Remote Wasre 392 During 15338 1200 0.0031 Decon Outside Work Area 43rd Floor Inside 393 During 15339 1200 <0.0023 Airlock Outside Work Area 43rd Floor 394 During 15340 1200 0.0027 Freight Elevator Lobby Outside Work Area 42nd Floor Inside 395 During 15341 1200 <0.0023 Airlock Outside Work Area 42nd Floor 396 During 15342 1200 0.0031 Freight Elevator Lobby Outside Work Area 41st Floor Inside 397 During 15343 1200 0.0033 Airlock Outside Work Area 41st Floor 398 During 15344 1200 <0.0023 Freight Elevator Lobby Outside Work Area 5th Floor Inside 399 During 15345 1200 0.0037 Airlock Outside Work Area 5th Floor Freight 400 During 15346 1200 0.0035 Elevator Lobby Outside Work Area Clean Room, of 401 During 15347 1350 <0.0020 Remote Personal Decon Outside Work Area Remote Waste 402 During 15348 1350 0.0022 Decon • Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. *** Laboratory QC data available upon request. **’* The laboratory has no control over air sampling collection. Reports are the confidential proper?/ of our clients. This certificate of analysis/report shall net be used by the client to claim product endorsement by ‘be .Vational Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full. without the written approval of Testwell Laboratories, Inc.

Deborah McCarl - Laboratory Director

Page 1 of 1

CITY_21MC100_011962989

NYC-WTC_000408786

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000408786Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →