TESTWELL LABORATORIES, INC. Environmental Laboratory NYSEWP# 111'12 47 Hudson Street, Ossining, New York 10562 NVWP t 200083-0 AIHA # 100147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 06/11/02 Date Rec'd (lab): 06/12/02 Project #: MBO-025AB Analysis Date: 06/12/02 Analyst: D. Agrest Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician B. Gitman

Sample Concentration Sample #; Sample Location; 02PCM # Volume Type f/cc

561 Outside Work Area Personal Decon During 16286 1300 0.0026

562 Outside Work Area Waste Decon During 16287 1300 0.0038 Outside Work Area 32nd Floor Inside 563 During 16288 1300 <0.0021 Airlock Outside Work Area 32nd Floor 564 During 16289 1300 0.0021 Freight Elevator Lobby Outside Work Area 33rd Floor Inside 565 During 16290 1300 <0.0021 Airlock Outside Work Area 33rd Floor 566 [During 16291 1300 <0.0021 Freight Elevator Lobby Outside Work Area 34th Floor Inside 567 During 16292 1300 0.0023 Airlock Outside Work Area 34th Floor 568 During 16293 1300 <0.0021 Freight Elevator Lobby

569 Outside Work Area Personal Decon During 16294 1300 0.0021

570 Outside Work Area Waste Decon During 16295 1300 0.0025 Outside Work Area 32nd Floor Inside 571 During 16296 1200 <0.0023 Airlock Outside Work Area 32nd Floor 572 During 16297 1200 <0.0023 Freight Elevator Lobby • Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. *” Laboratory QC data available upon request. **** The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full. without the written approval of Testwell Laboratories, Inc.

Deborah McCari - Laboratory Director

Page 1 of 1

CITy_21MC100_011963023

NYC-WTC_000408820

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000408820Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →