Appendix K: post-WTC indoor dust test results

Machine-extracted title · confidence 44%

Indoor air/dust tests after WTC collapse; metals, PCBs, dioxin analyses; one sample above standard.

NYC-WTC_000408671–000408676
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

PCM Results {9.01 f/cc) TEM Results (70 s/mm2) Location Sampling Period No. of No. above No. of No. above 0.01 f/cc Samples 290 Broadway 09/13/01 -09/28/01 18 0 58 0 10/09/01-10/23/01 16 0 16 0 12/03/01 -01/02/02 21 0 21 0 1 Bowling Green 10/12/01-10/25/01 18 0 16 0 Note; All results were non detect except for 4 of the 58 samples collected between 9/13/01 and 9/28/01. Two of these sample showed asbestos levels of 25 s/mm2 by TEM and 2 samples could not be analyzed because of overloaded filters.

K-6; Asbestos Dust Testing at 290 Broadway Sample Collection Information PLM No. of Samples No. of Samples Date Type 2!2_ Asbestos Detected Asbestos Detected 09/14/01 Vacuum 5 Not Analyzed 5 09/14/01 Tape 5 0 0 09/14/01 HVAC Filter 3 0 0

K-7: Non-Asbestos Air Sampling Results 290 Broadway 500 Pean Street Screening No. Above No. Above Pollutant Test Method No. of No . of Screening Screening Samples Samples Level Lead 50 ug/m3 NIOSH 7082 3 0 6 0 Respirable Dust 5.0 mg/m3 NIOSH 0600 3 0 6 0 Carbon Dioxide 5000 ppm Telaire CO2 3 0 6 0 Carbon Monoxide 50 ppm SGA91 3 0 6 0 VOCs 1 ppm [1] H-Nu Photo 3 0 6 0 [1] = Method Detection Limit

Other Indoor Air Studies

“Characterization of Particulate Found in Apartments After Destruction of the World Trade Center.”’** This study was conducted at the request of the Ground Zero Elected Officials Task Force. This study selected two residential apartment buildings for sampling - one presumed to have significant WTC dust contamination and the other not - based on their locations. Six air samples were collected from inside one apartment building and five from the other. All 11 samples were analyzed by the TEM method. The study found higher levels of

I8 Eric J. Chatfield, Ph.D., Chatfield Technical Consulting Limited, and John R. Kominsky, M.Sc.,CIH, CSP, CHMM, Environmental Quality Management, Inc.; October 12, 2001. 97 Report No. 2003-P-00012

CITY_DEP_WORBY_CANNATA_SUBP_000019080

NYC-WTC_000408675

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000408675Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →