NYC 9/11 Public Portal Document
KAM CONSULTANTS
S5-40J6th Street
Lang Island City
New York, 11106
Tel: 718 729-1907
Fax: 718 729-1876
ANALYSIS REPORT
ASBESTOS IN AIR
Transmission Electron Microscopy
CLIENT: Department of Design and Construction - 30-30 Thomson Avenue, Long Island City, NY 11101
PROJECT ADDRESS: Stu>Aesant H.S., 345 Chambers St, NY, NY 10282 Pier #25
q LablD^ Client Sample Location. Volume Grid Filter Anahtical Asbestos Asbestos Structures Detected Structure Density Structure
Sample (liters) Openings Area Sensitivity T3Tc(s) (microns) (struc/mm^) Tclal Concentration
H ID# Examined (mm^) (struct/cc air) (struc/cc)
O O.5-5.O >5.0 Total Total
Td T020309A-01 1 North Exit of Stiiyvesant H.S. 1800 6 385 0.0043 ND 0 0 0 <20.00 <0.0043
O
H ■i'U'2U3CyA-02 2 North West Site Stuyvesant H.S. 1800 6 385 0.0043 ND 0 0 0 <20.00 <0.0043
n Q
o O
H 2
a
o s
U
n
2^
O
Area Analyzed; 0.0600 nm? Date Received: 03/09/02
Grid Opening Area: 0.010 mm' Date Analyzed: 03/09/02
Date Collected: 03/08/02(07:00-17:00) Date of Report: 03/12/02
^'Knalyst: Lab Manager:
Q Alex Barengolt? David Chen
Analysis perfonued according to AI CORA Method (EPA 40 CFR Part 763 - Appendix A). Samples v\'ill be stored for ninety (90) days and then returned to the client upon request.
Sample volume is below recommended limit of the method
1^ AIHA#: 100269 NIST-NVLAP #: 102047 NYS-DOH ELAP#: 11273
to
S
o
Page 1 of 1
Ln
st)
NYC-WTC_000408190