NYC 9/11 Public Portal Document

Draft Proposed Sampling Strategy for the WTC Site: 9/25,111

OJ a Task Potential Hazards Minimum Number of Q_ Samplcs/Day Iron workers (torch cutters, etc.) Metals, Fire decomposition productst, Carbon monoxide. Ozone, Asbestos 6 to 10

Fire fighters/poiice (on debris pile) Fire decomposition productsf. Carbon monoxide, Asbestos 6 to 10 Fire fighters/poiice (off debris pile) Diesel exhaust 2 to 5 Heavy equipment operators (crane, bobcat, Fire decomposition productst. Carbon monoxide. Noise, Asbestos 6 to 10 fixml'end loaders, high reach machines) co LO CO USAR (urban search and rescue teams) Fire decomposition productst. Carbon monoxide. Asbestos 6 to 10 w—• tn Traffic controllers in the restricted area Carbon monoxide, Diesel exhaust, Noise 2to5 Truck drivers (leaving the site) Diesel exhaust, Asbestos 2to5 su. Site access personnel (i.e. checkpoints on the Carbon monoxide 2to5 perimeter of the site) t For the V»TC site, the fire decomposition products group is defined to include the following aromatic hydrocarbons; toluene, xylene, and ethylbenzene. Total hydrocarbons (quantified as undecane [C,,] and reported in milligrams per cubic meter) should also be reported.

Suggested sampling methods;

Metals: NIOSH Method 7300 - Elements Carbon monoxide: Direct-reading dosimeter Diesel exliaust: NIOSH Method 5040 I Aromatic Hydrocarbons: NIOSH Method 1501 Noise: Type 11 noise dosimeters (initial characterization may be done with a Type H sound level meter) x: cx« Ozone: Direct-reading instrument Asbestos: NIOSH 7400 (PCM), NIOSH 7402 (TEM) O o CO H O Other potential exposures; 1"^

S g NIOSH investigators have collected samples for the following substances and are currently awaiting the analytical results: polynuclear aromatic hydrocarbons Q o [PAIIs]; mercury; crystalline silica, polychlorinated biphenyls (PCBs). I—i o o cu o I Io Lf> NOTE; Those with oversight responsibilities for characterizing occupational exposures at the WTC site should be cognizant of the fact that this work site is a CU I cu dynamic environment and worker exposures may change depending on weather conditions and type of debris being removed. Tlic type of personal UJ CO co co monitoring may need to be adjusted based on these factors, 7 (JI CO

NYC-WTC_000407825

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407825Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →