NYC-WTC_000308177
World Trade Center air sampling table with fiber and PCM results by site.
2 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗DEP Bureau results of environmental compliance sampling; asbestos-focused.
NYC-WTC_000407511–000407513OCR status: ok · source: pdftotext
Z Z o o g CD
o I “0 o o o NYC DEPARTMENT OF ENVIRONMENTAL PROTECTION c CT
o o' cn BUREAU OF ENVIRONMENTAL COMPLIANCE "0 o RESULTS OF ASBESTOS AIR MONITORIN REGULATORY LIMIT 0.01 f/cc o No Date PS 314K IS 155 PS 64 PS 199 Susan Wagner H. S. o o c 330 59th Street, Bk Jackson & E 148, BX 600 East 6th Street, MN 30-20 48th Street, Qn 1200 Manor Road, SI 3 CD 3
1 09/14/01 0.003 f/cc NA < 0.001 f/cc 0.002 f/cc 0.005 f/cc 2 09/14/01 0.003 f/cc NA 0.002 f/cc 0.002 f/cc 0.004 f/cc o o z 3 09/15/01 < 0.001 f/cc 0.003 f/cc 0.002 f/cc < 0.001 f/cc < 0.001 f/cc o m 4 09/15/01 < 0.001 f/cc 0.003 f/cc 0.003 f/cc 0.002 f/cc < 0.001 f/cc CO c 5 09/15/01 < 0.001 f/cc < 0.001 f/cc < 0.001 f/cc < 0.001 f/cc < 0.001 f/cc CD m O 6 09/16/01 0.006 f/cc < 0.001 f/cc 0.008 f/cc 0.002 f/cc 0.003 f/cc o □3 7 09/16/01 0.004 f/cc 0.003 f/cc 0.002 f/cc 0.003 f/cc 0.002 f/cc O -I m O 8 09/16/01 0.002 f/cc < 0.001 f/cc 0.004 f/cc < 0.001 f/cc < 0.001 f/cc m O 9 09/16/01 NA NA 0.006 f/cc NA NA □3 o m □3 10 09/17/01 0.002 f/cc 0.002 f/cc < 0.001 f/cc 0.002 f/cc 0.002 f/cc z p 11 09/17/01 < 0.001 f/cc <0.001 f/cc < 0.001 f/cc 0.002 f/cc < 0.001 f/cc Q I 12 09/17/01 0.002 f/cc < 0.001 f/cc 0.001 f/cc 0.002 f/cc 0.003 f/cc __ 1 o
o 13 09/18/01 < 0.001 f/cc < 0.001 f/cc 0.002 f/cc <0.001 f/cc < 0.001 f/cc m 14 09/18/01 < 0.001 f/cc < 0.001 f/cc 0.002 f/cc < 0.001 f/cc < 0.001 f/cc o □3 15 09/18/01 < 0.001 f/cc <0.001 f/cc 0.001 f/cc < 0.001 f/cc < 0.001 f/cc DO
> 16 09/19/01 <0.001 f/cc 0.002 f/cc < 0.001 f/cc < 0.001 f/cc < 0.001 f/cc z z < 0.001 f/cc < 0.001 f/cc > 17 09/19/01 < 0.001 f/cc 0.002 f/cc < 0.001 f/cc cn 18 09/19/01 < 0.001 f/cc < 0.001 f/cc < 0.001 f/cc < 0.001 f/cc < 0.001 f/cc c DO 'o 8o o 8co co
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000308177
World Trade Center air sampling table with fiber and PCM results by site.
2 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000361867
Air sampling at Center Chambers and Broadway WORTH area with PCM/TEM.
2 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308185
WTC air sampling table with locations Greenwich/Chambers and related measurements and LOQ.
2 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209346
Summary table of air sample results collected from various street intersections in the Financial District on September 12.
2 shared non-person entities · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306713
Entry showing sample IDs, locations, and PCM/LOQ data for WTC air sampling.
1 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306711
Table of air sample IDs, locations, and preliminary PCM results from WTC area sampling in Sept 2001.
1 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000332422
Asbestos air sampling table for WTC area with PCM results and LOD/LOQ data.
1 shared non-person entities · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306712
Air sampling table listing sample IDs and analysis for WTC site, Sept 2001.
1 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333182
Lab results for ambient/indoor sampling at Greenwich & Chambers and other Broadway sites.
1 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000361872
Ambient air PCM readings at WTC sites near Wall Street area.
3 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333185
Asbestos air sample table with PCM/TEM results for WTC area, 9/12/01.
1 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161628
Document discussing limitations of ASTM D5755-95 and D6480-99 for asbestos fiber sampling and lack of safety standards.
3 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000161893
Report from the NYC Department of Environmental Protection showing asbestos air monitoring results for October 2001.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161893
Report from the NYC Department of Environmental Protection showing asbestos air monitoring results for October 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330824
Department of Environmental Protection asbestos air results with multiple sites.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330824
Department of Environmental Protection asbestos air results with multiple sites.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307241
Asbestos air monitoring results across multiple facilities with regulatory limits.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307229
Results of asbestos air monitoring for multiple PS and IS locations with regulatory limits.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000161628
Document discussing limitations of ASTM D5755-95 and D6480-99 for asbestos fiber sampling and lack of safety standards.
Similar indexed content
NYC-WTC_000308177
World Trade Center air sampling table with fiber and PCM results by site.
Similar indexed content
NYC-WTC_000361867
Air sampling at Center Chambers and Broadway WORTH area with PCM/TEM.
Similar indexed content
NYC-WTC_000308185
WTC air sampling table with locations Greenwich/Chambers and related measurements and LOQ.
Similar indexed content
Summary table of air sample results collected from various street intersections in the Financial District on September 12.
Similar indexed content