Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
we Analytical_________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client's Sample ID ATC-0403-STY-DX2
Lab Sample ID 103451282
Filename U20502B_05
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/03/2002
ICAL Date 04/16/2002 Received 04/09/2002
CCal Filename(s) U20502B_02 & U20502B_12 Extracted 04/24/2002
Method Blank ID BLANK-1588 Analyzed 05/03/2002 00;00
Native Cone EMPC LRL Internal ng'S Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
1 2,3,7,8-TCDF
Total TCDF
----
0.150
0.0081
----
0.0037 EA
0.0020
2,3,7,8-TCDF-13C
2,3,7.8-TCDD-13C
2.00
2.00
64
70
1,2,3,7,8-PeCDF-13C 2.00 61
2.3,7,8-TCDD ND 0.0036 A 2,3,4,7,8-PeCDF-13C 2.00 60
1 Total TCDD 0.340 0.0020 B 1,2,3,7,8-PeCDD-13C 2.00 66
1.2,3.4,7,8-HxCDF-13C 2.00 90
1,2,3,7.8-PeCDF ND 0.0100 1,2.3,6,7,8-HxCDF-13C 2.00 80
2,3,4,7,8-PeCDF ND 0.0100 2,3.4,6,7,8-HxCDF-13C 2.00 80
1 Total PeCDF 0.041 0.0100 J 1.2,3,7,8,9-HxCDF-13C
1,2,3,4.7,8-HxCDD-13C .
2.00
2.00
82
95
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 79
Total PeCDD 0.092 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 83
1,2,3,4,7,8,9-HpCDF-13C 2.00 85
1,2.3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 91
1,2,3,6,7.8-HxCDF ND 0.0100 OCDD-13C 4.00 78
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3.7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
j Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 76
1,2.3,6.7.8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.033 0.0100 J
1.2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.000063 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
I OCDD 0.063 0.0200 BJ
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EM PC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
1 Nn = Value obtained from additional analysis
! ’ = See Discussion
Report No..... 02-1056079
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full.
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003797483
NYC-WTC_000406230