NYC 9/11 Public Portal Document
104 East 25th St., 10th Floor
New York, New York 10010
www.atc-enviro.com
212.353.8280
Fax 212.353.8306
ASSOCIATES INC.
July 10, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Silica
Stuyvesant High School
ATC Project No. 15-19125-0246
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for silica-containing
dust conducted on April 3, 2002 at the referenced school. The New York City Board of
Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant to
the parents’ association.
Scope of Work
ATC collected twelve (12) samples for respirable dust using pre-weighed 37mm PVC filters
connected to size-selective cyclones to remove the larger (non-respirable) particles prior to
deposition on the filters. One (1) outdoor sample and eleven (11) indoor samples were collected.
The samples, plus a blank, were sent to PSC Analytical Services, Inc., an American Industrial
Hygiene Association accredited laboratory in Reading, PA. Analysis was performed by x-ray
diffraction according to OSHA Method 142. A copy of the analytical report is attached.
Wagdi Abdelshahid Industrial Hygienists from ATC’s New York City office, conducted the
sampling. The results represent conditions on the day the samples were collected.
The sampling locations were: L‘ Floor Main Lobby, Auditorium, Pool, 2"“^ Floor Main Stair, 3^**
floor Gym, 3'‘^ floor Hallway center, 5* floor cafeteria, 5* floor Hallway center. Room #511
(South), Room # 701 (East), Room # 836 (North) and Outdoors East.
Results
Silica was found above the limit of detection in one of the samples. Sample # ATC-0403-STY-
S4, collected in Auditorium, contained 0.0123 milligrams of silica per cubic meter of air (mg/m’).
Silica was not detected above the analytical limit of detection in any of the remaining samples.
The Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL)
for silica-containing dust is based on the percent of quartz (SiO2) found in the dust, the higher the
percentage of quartz, the lower the PEL.