Mr. Bernard P. Orlan May 13,2002 Air Sampling for Metals Page 2 Stuyvesant High School ATC Project No. 15-19125-0246

The Cr concentrations indoors were 0.000348 mg/m’ (0.348 ug/m’) and 0.000373 mg/m ' (0.373 ug/m’. The outdoor (roof) sample contained 0.000346 mg/m’ (0.346 ug/m’).

The blank-corrected Cr concentrations indoors were 0.000257 mg/m’ (0.257 ug/m’) and 0.000233 mg/m^ (0.233 ug/m’). The roof sample contained a blank-corrected concentration of 0.0001062 mg/m’ (0.106 ug/m’). Two blanks were submitted on this date to better evaluate the trace metal content of the filters. Cr was detected in both blank sample.

The Environmental Protection Agency has recommended a screening level for hexavalent Cr (the more toxic form) of 0.6 micrograms per cubic meter of air (0.6 ug/m’) based on continuous exposure for one year. These samples were analyzed for total Cr. The blank-corrected Cr level was below the limit of detection

April 17

The metals detected inside the building were Cr and Pb. Cr, Pb, Fe, and Ni were detected on the roof. Cr and Pb were also detected in both blank. Two blanks were submitted on this date to better evaluate the trace metal content of the filters.

Cr concentrations indoors were 0.000529 mg/m’ (0.529 ug/m’) and 0.000355 mg/m’ (0.355 ug/m’). Pb concentrations indoors were 0.000335 mg/m’ (0.335 ug/m’) and 0.000394 mg/m’ (0.394 ug/m’). The outdoor (roof) sample contained Cr concentrations at 0.000501 mg/m’ (0.501 ug/m’), Pb concentrations at 0.000501 mg/m’ (0.501 ug/m’), Fe concentrations at 0.00325 mg/m’ (3.25 ug/m’), andNi concentrations at 0.000501 mg/m’ (0.501 ug/m’).

The blank-corrected indoor Cr and Pb level were below the limit of detection. The blank- corrected outdoor Cr, Pb, and Fe level were below the detection limit. The blank-corrected outdoor Ni level was 0.00104 mg/m’ (1.04 ug/m’).

The established regulatory values for metals in air are intended for industrial workplace exposures and are not generally applicable to office/school settings. There are no standards for metals in indoor air in non-industrial situations.

The EPA ambient air quality standard for Pb is 1.5 ug/m^ for a three-month exposure.

The Environmental Protection Agency has recommended a screening level for hexavalent Cr (the more toxic form) of 0.6 micrograms per cubic meter of air (0.6 ug/m’) based on continuous exposure for one year. These samples were analyzed for total Cr.

The EPA screening level for Ni is 2.0 ug/m\ also based on a continuous one-year exposure.

The levels detected were below the EPA standards and screening levels.

The EPA has no guidelines or screening levels for Fe.

CITY_21MC100_000492235 NYC-WTC_000406038

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000406038Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000395394

Air sampling for metals at Stuyvesant High School, BOE-initiated.

Similar indexed content

Compare copies and versions →