NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Air sampling metals, Stuyvesant HS, 2002

Machine-extracted title · confidence 52%

ATC report of metals air sampling at Stuyvesant High School in March–April 2002.

NYC-WTC_000406048–000406050
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan May 2,2002 Air Sampling for Metals Page 2 Stuwesant High School ATC Project No. 15-19125-0246

The Cr concentrations indoors were 0.000292 mg/m^ (0.292 ug/m^) and 0.000359 mg/m’ (0.359 ug/m\ The outdoor (roof) sample contained 0.000346 mg/ni^ (0.346 ug/m’).

Fe was detected in the 2"^ floor Bridge Entrance Lobby at 0.00352 mg/m’ (3.52 ug/m’) and 0.00315 mg/m’ (3.15 ug/m^) on the Roof.

The Pb concentrations indoors were 0.000317 mg/m’ (0.317 ug/m’) and 0.000360 mg/m^ (0.360 ug/m’. The outdoor (roof) sample contained 0.000340 mg/m^ (0.340 ug/m’).

Mn was detected in the 2"** floor Bridge Entrance Lobby at 0.000487 mg/m’ (0.487 ug/m’) and 0.000455 mg/m’ (0.455 ug/m’) on the Roof.

The blank-corrected Zn concentrations indoors were 0.000514 mg/m^ (0.514 ug/m^) and 0.00181 mg/m’ (1.81 ug/m\ The roof sample contained a blank-corrected concentration of 0.00165 mg/m’(1.65 ug/m’).

March 20

The metals detected in the samples were Cr and Pb. Al, Cu and Ph were detected in the blank.

Cr concentrations indoors were 0.000639 mg/m’ (0.639 ug/m’) and 0.000852 mg/m’ (0.852ug/m’). The outdoor (roof) sample contained 0.000813 mg/m^ (0.813 ug/m’).

The blank-corrected indoor Pb level was below the limit of detection for the one sample (Bridge Entrance Lobby) in which Pb was found.

March 27

The metals detected in the samples and in the blank were Al and Cr.

The blank-corrected Cr concentrations were 0.000304 mg/m’ (0.304 ug/m’) and 0.000143 mg/m’ (0.143 ug/m’) indoors and 0.000396 mg/m’ (0.396 ug/m’) outdoors. The blank-corrected Al concentrations were 0.000531 mg/m’ (0.531 ug/m’) or less.

April 3

The metals detected in the samples and in the blank were Al and Cr. Two blanks were submitted on this date to better evaluate the trace metal content of the filters. One blank contained both Al and Cr, the other contained only Cr.

Indoor blank-corrected Cr concentrations were 0.000063 mg/m^ (0.063 ug/m^) and 0.000151 mg/m’ (0.151ug/m’). The blank-corrected outdoor (roof) concentration was 0.000169 mg/m^ (0.169 ug/m’). The blank-corrected Al concentrations were below to just above the limit of detection.

The established regulatory values for metals m air are intended for industrial workplace exposures and are not generally applicable to office/school settings. There are no standards for metals in indoor air in non-industrial situations.

CITY_21MC100_000492247 NYC-WTC_000406049

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000406049Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000312782

Air sampling results for metals at Stuyvesant High School; May 2002 report.

Similar indexed content

NYC-WTC_000238215

Letter report from ATC Associates detailing air sampling for metals conducted at Stuyvesant High School between March and April 2002.

Similar indexed content

Compare copies and versions →