NYC-WTC_000292246
TEM analysis data for NYC BOE air samples; includes grid, magnification, and date.
7 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
NYC-WTC_000405307OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet Client Name: NYC BOE Volume (liters): 1800 Lab Group #: 7636 Filter Type / Filter Area: MCE 385 mm’ Lab Sample #; 11 Grid Opening Size: 0.01124 Client Sample #: 14 Area Examined: 0.04496 mm’ GRID BOX: Magnification: 20 000 GRID ID: Accelerating Voltage: 100 KeV # Grid Openines: 4 Analysis Pate: 5/4/02
Analysis Performed By: ROMAN PEYSAKHOV
GO, Structure Structure Type Length ID of Structure N or -/ EDS
No Coord No F S c >=05 y <Sy >=StJ Chrys Aniphibole Noflasb Amtng#JD (Nonadb Elements)
g® z/
J
Struct = >0.Sp >5:1 Aspect Ratio Grid acceptance: Pdsittve diffraction pattern properties conforming to <50% undiesolved filler, overlapped or fa ded Totals laboratory identification criteria observed <10% particulate coverage >50% coverage ate (east 20 unfolded or oradapped grid squares <5% F B C M v'= EDS spectrum conforming to laboratory holes Of opaque areas identificallon criteria observed Chrysotile AMPHIBOLES Amphibole F = Single Fiber Amosite a ■= Bundle (<3 fibers <1 liber diameter apart Crocidolite Ambiguous C = Cluster (>3 Intersections) Anthrophyllite Non-Asbestos Tremolite M - Matrix Actinolite Non-Identified NSD = No Structures Detected
CITY_21MC100_002901644
NYC-WTC_000405307
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000292246
TEM analysis data for NYC BOE air samples; includes grid, magnification, and date.
7 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000227666
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195032
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000222360
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292221
TEM analysis data for NYC BOE air samples; includes grid, magnification, and date.
7 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292078
TEM asbestos air analysis at NYC BOE site, May 2002.
7 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292385
TEM asbestos analysis data; May 18, 2002.
7 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000222207
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274408
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292032
TEM asbestos air analysis data for BOE project 7603, June 2002.
7 shared non-person entities · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000194566
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000213643
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000227666
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195032
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000222360
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000222207
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000295247
TEM asbestos analysis results for PS 234M project, Mar 15, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274408
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000292246
TEM analysis data for NYC BOE air samples; includes grid, magnification, and date.
Similar indexed content
NYC-WTC_000227666
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similar indexed content
NYC-WTC_000195032
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similar indexed content
NYC-WTC_000222360
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similar indexed content
NYC-WTC_000292221
TEM analysis data for NYC BOE air samples; includes grid, magnification, and date.
Similar indexed content