104 East 25th S New York, New York 10O1C www.atc-envirQ.con 212.353.828( Fax 212.353.830( AS so C I A T E S INC.

February 21,2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Samples for Metals P.S.89M ATC Project No. 15-19125-0297

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for metals in airborne dust conducted on February 7, 2002, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of Environ Corp., a consultant retained by the parents association.

ATC collected four (4) samples for metals at specified locations. Samples were collected for a minimum of ten (10) hours using 37 mm mixed cellulose ester filters connected to battery- powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and after each sampling period. One (1) sample was collected inside the building and three (3) were collected outdoors. One blank sample was also submitted. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was performed by NIOSH Methods 7300M. Each sample was analyzed for a panel of eleven (11) metals. The metals were aluminum (Al), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni) and zinc (Zn). A copy of the analytical report is attached.

The sampling locations were the 1’‘ floor Hallway by the Cafeteria, Playground (north side). Playground (south side) and the Roof.

The established regulatory values for metals are intended for industrial workplace exposures and are not generally applicable to office/school settings. There are no standarcb for these metals in indoor air in non-industrial situations.

AIR SAMPLE RESULTS

The metals that were found above the limits of detection were chromium (Cr) and iron (Fe). The other metals were not detected, Cr has been consistently found in the blank filters. When the concentration of Cr in the blank is subtracted from those in the samples, the concentrations fall below the limits of detection. Fe was detected in one sample (M2, Playground-north) at 3.63 micrograms per cubic meter (ug/m’).

CITY_21MC100_002899730

NYC-WTC_000403813

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000403813Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →