TEM Lab Data, PS 89M, 3/19/02

Machine-extracted title · confidence 33%

Lab data sheet: TEM analysis parameters and image data.

NYC-WTC_000403625
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TEM Ast tos (air) Count Sheet Cliept Name: NYC BOE Volume (liters); 1800 Lab Group #: 7131 Filter Type / Filter Area: MCE 385 mm’ Lab Sample #: 12 Grid Opening Size: 0.01124 Client Sample #: 12 Area Examined; 0.04496 mm^ GRID BOX: Magnification: 20,000 GRIP ID: Accelerating Voltage; 100 KeV # Grid Openings: 4 Analysis Date: 3/19/02

Analysis Performed By; MARKPEYSAKHOV

' GO. Structure Structure Type Length IDofStnicture Nor v EDS (Nonadb No F B C M >=05 p >=5p Chrys Amphibole Nonasb Ambig/ND ! No .Coord <5p Elements)

Struct ” > 0.5(1 .> 5:1 Aspect Ratio Grid acceptance: ^/=Posltivedlff^actionpmte^tproperfi^ Totals .............. -.............. laboratory Identification criteria observed <10% parnonto coverage >50% coverage ate least 20 unfolded or overiapped grid squares <5% F B C M ■'/= EDS spectrum conforming to laboratory holes or opaque areas idenfation criteria observed Chrysotile AMPHIBOLES Amphibole F = Single Fiber Amosite B = Bundle (<3 fibers <1 fiber diameter apart Croddolite Ambiguous C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos Tremolite M = Matrix Actinolite Non-Idcntificd NSD = No Structures Detected

CITY_21MC100_006617743

NYC-WTC_000403625

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000403625Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM report, PS 89M, Feb 2002

NYC-WTC_000403200

TEM analysis results for air samples at PS 89M playground and roof areas.

Similar indexed content

Compare copies and versions →