NYC-WTC_000255807
ATC memo reporting IAQ measurements at Stuyvesant High School, Jan 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Indoor air quality measurements report for Stuyvesant High School dated January 10, 2002.
NYC-WTC_000401773–000401776OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
OBSERVATIONS
During this assessment, ATC noted the following: • The interior of the building appeared clean and free of dust and debris; • The building was occupied at the time of the assessment; • -No smoke odor was detected in the building; • At the time of ATC’s site visit, room 125 was occupied by approximately 150 people.
FINDINGS
Based on the real-time measurements, the following findings are presented:-
1. Concentrations of respirable particulates, CO and TVOCs were within applicable standards and guidelines.
2. Twelve (12) CO2 measurements were above the range recommended by ASHRAE 62-1999 All others were below the recommended maximum concentration. fe
3, Five (5) indoor measurements of relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. All other relative humidity measurements were below the ASHRAE-recommended range.
4. Twenty-three (23) temperature measurement was above the range of 68 to 75°F (at 50 ■fe 1 5 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions).
lt is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 261 or 212. ;. ;> .
Sincerely, A TC ASSOCIA TES INC. Reviewed by:
Andreas C. Andreou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division
Attachment
■a SI
CITY_21MC100_002897741
NYC-WTC_000401776
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000255807
ATC memo reporting IAQ measurements at Stuyvesant High School, Jan 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311232
ATC report of IAQ measurements at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311250
ATC report of IAQ measurements at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401743
Indoor air quality measurements report for Stuyvesant High School, January 8, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255777
ATC memo detailing IAQ measurements at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311194
ATC report of indoor air quality measurements at Stuyvesant High School (M477).
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401790
ATC reports IAQ measurements taken January 11, 2002 at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401819
ATC indoor air quality report dated January 16, 2002 for Stuyvesant High.
13 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311190
ATC report on indoor air quality measurements at Stuyvesant High School (M477).
10 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274045
December 20, 2001 IAQ measurements at Stuyvesant High School for BOE.
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401524
Indoor air quality measurements conducted December 17–18, 2001 at Stuyvesant High School.
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311269
ATC report of IAQ measurements collected at Stuyvesant High School.
13 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000255807
ATC memo reporting IAQ measurements at Stuyvesant High School, Jan 2002.
Similar indexed content
ATC report of IAQ measurements at Stuyvesant High School.
Similar indexed content
NYC-WTC_000311250
ATC report of IAQ measurements at Stuyvesant High School.
Similar indexed content
NYC-WTC_000401743
Indoor air quality measurements report for Stuyvesant High School, January 8, 2002.
Similar indexed content
NYC-WTC_000255777
ATC memo detailing IAQ measurements at Stuyvesant High School.
Similar indexed content