NYC-WTC_000401394
Indoor air quality measurements at Stuyvesant High School, December 4, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Indoor air quality report for Stuyvesant High School dated December 3, 2001.
NYC-WTC_000401380
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
104 East 25th Street New York, New York 10010 www.atc-enviro.com" 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.
December 4, 2001
Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education .28-11 Queens Plaza North Long Island City, NY 11101-4008
Re: Indoor Air Quality Assessment Stuyvesant High School (M477) 345 Chambers Street New York, New York 10007 ATC Project No. 15-19125-0246
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of indoor air quality (lAQ) measurements collected on December 3, 2001, at the referenced school. The New York City Board of Education (BOE) requested these measurements as part of a program to determine if acceptable indoor air quality is being maintained.
SCOPE OF WORK
ATC conducted this evaluation to assess the basic parameters of temperature, relative humidity, carbon dioxide (COj) and carbon monoxide (CO).
Total volatile organic compounds (TVOCs) and respirable particulates were also measured.
Jimmy Choy, Industrial Hygienist, of ATC’s New York City office, conducted the assessment. ATC’s findings and conclusions are based on a visual inspection, real-time environmental measurements and conditions present in the school at the time of the assessment.
ATC measured temperature, relative humidity, CO, and CO with a Q-Trak® Model 8551, manufactured by TSI, Inc.
ATC measured concentrations of respirable particulates (PM2.5) with a Dust-Trak® Aerosol Monitor Model 8520, manufactured by TSI, Inc.
ATC measured concentrations of TVOCs using a RAE Systems, Inc. MiniRAE® photoionization detector (PID).
The assessment was performed consistent with generally accepted indoor air quality assessment practices. As with all such assessments, there were inherent limitations created by constraints of time, operational and work practice variability, variations in indoor air quality parameters and
CITY_21MC1OO_OO2897199
NYC-WTC_000401380
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000401394
Indoor air quality measurements at Stuyvesant High School, December 4, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293274
Memo reporting indoor air quality measurements taken at Stuyvesant High School in November 2001.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401631
ATC memo transferring indoor air quality report for Stuyvesant High School to NYC BOE.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000227005
Report letter from ATC Associates detailing indoor air quality measurements collected at Stuyvesant High School in December 2001.
8 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401702
Indoor air quality measurements report for Stuyvesant High School, January 2002.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401436
Report of IAQ measurements collected December 7, 2001 at Stuyvesant High School, NYC.
8 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401690
ATC IAQ measurements report for Stuyvesant High School dated Jan 28, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293260
ATC report delivering indoor air quality measurements to NYC Board of Education.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401659
ATC memo confirming IAQ measurements at Stuyvesant High School on January 24, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401714
Indoor air quality report documenting measurements at Stuyvesant High School.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401726
Indoor air quality measurements report for Stuyvesant HS dated Jan 31, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401892
Indoor air quality report dated February 4, 2002 for Stuyvesant High.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000401450
Indoor air quality measurements conducted December 10, 2001 at Stuyvesant High School.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273995
December 2001 IAQ measurements at Stuyvesant High School with BOE contact.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401502
Indoor air quality measurements collected December 13, 2001 at Stuyvesant High School.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274045
December 20, 2001 IAQ measurements at Stuyvesant High School for BOE.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273973
Memorandum regarding indoor air quality measurements at Stuyvesant High School.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311292
ATC report of IAQ measurements at Stuyvesant High School (M477).
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000401394
Indoor air quality measurements at Stuyvesant High School, December 4, 2001.
Similar indexed content
NYC-WTC_000293274
Memo reporting indoor air quality measurements taken at Stuyvesant High School in November 2001.
Similar indexed content
NYC-WTC_000401631
ATC memo transferring indoor air quality report for Stuyvesant High School to NYC BOE.
Similar indexed content
Report letter from ATC Associates detailing indoor air quality measurements collected at Stuyvesant High School in December 2001.
Similar indexed content
NYC-WTC_000401702
Indoor air quality measurements report for Stuyvesant High School, January 2002.
Similar indexed content