NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 29, 2002
Air Sampling for Hydrocarbons Page 2
Stuvvesant High School ATC Project No. 15-19125-0246
RESULTS
March 20
The only hydrocarbon in the analyte panel that was detected was acetone. Acetone was found at
0.12 parts per million (ppm) in the roof (outdoor) sample. It was also detected at a greater
concentration in the blank. Acetone was not detected in the indoor samples. The results indicate
that acetone was most likely a trace contaminant of the sample medium.
The EPA has issued no ambient air standard or guideline for acetone. The level detected here is
far below the occupational standard for this compound (OSHA Permissible Exposure Limit for
acetone: 1,000 ppm).
March 27
None of the hydrocarbons in the analyte panel were present above the limits of detection.
ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call
me at (212) 353-8280 extension 212 if you have any questions.
Sincerely,
ATC Associates, Inc.
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Division
Attachment
CITY_21MC100_002897187
NYC-WTC_000401369
OCR can misread numbers and units. Confirm readings against the page image before using them.