Mr. Bernard P. Orlan March 29, 2002
Air Sampling for Hydrocarbons Page 2
Stuyvesant High School ATC Project No. 15-19125-0246
RESULTS
Three of the hydrocarbons in the analyte panel were detected in the samples. These were 1,2
dichloroethane (ethylene dichloride), acetone and hexane. All three were detected in the roof
(outdoor) sample, 1, 2 dichloroethane and hexane were detected in the main lobby, acetone and
hexane were detected in the bridge entrance lobby. The concentrations are shown in the table.
HYDROCARBONS DETECTED
March 13,2002
'EfTON
Floor Lobby
VOCl 0.057 *BDL 0.29
Bridge Entrance
Lobby, VOC2 BDL 0.50 0.25
Roof
VOC3 0.057 0.83 0.34
Blank
BDL
1
VOC4 BDL BDL
OSHA Permissible
Exposure Limit 50 1000 500
* Below Detection Limit
1, 2 dichloroethane (ethylene dichloride) is an industrial solvent for waxes, oils, resins and rubber
and is also used as a fumigant. The source in and around the school is unknown. Acetone is a
common solvent in a variety of industrial processes and is the principal component nail polish
remover. Hexane is another common solvent and is used in the school by ATC to collect wipe
samples for PCBs and dioxin.
There are no ambient air standards for these hydrocarbons and the levels detected here are far
below the occupational standards for these compounds (see Table).
ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call
me at (212) 353-8280 extension 212 if you have any questions.
Sincerely,
ATC Associates, Inc.
James R. Cohn, CIH, CSP
Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_002897179
NYC-WTC_000401362