NYC-WTC_000401298
ATC analytical report for 19125-0246; samples collected 12/20/01.
7 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Analytical report for ATC Associates hydrocarbon sampling at a NYC school (Jan 29–30, 2002).
NYC-WTC_000401309–000401311OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
PSC Rnalytical Ser^vices 6109219667 P-3 Jan 30 02 04:34p
page 1 of 3 30JAN02_1345_!3_N1261_RFR
FSC INDUSTRIAL HYGIENE
• EPA;NVL4P 101262-0 • AIHA ACCREDITATION NO. W043S - NC DENF; 599 ENVIRONMENTAL TESTING • NY DOH/NELAC 10S03 • PA DEP 06-353 • NJ DEP 77020 . CT DPH PH.0238
ANALYTICAL SERVICES
ANALYTICAL REPORT
Client: ATC Associates Project; 209472 Received: 25-JAN-02 Report to; James Cohn Reported; 30-JAN-02 ATC Associates 104 East 25th Street 10th Floor New York NY 10010-2917
Project Description: 19125-0246 / HCs A&B
Sampled: 23-JAN-O2
RESULT UNITS CONCENTRATION UNITS METHOD I Hl
ATC-0123-STY-VOC 1 Air Volume: 96 L Lab Sample; 1476665
Pentane < 0.020 mg/sample < 0.071 ppm 1500 Acetone < 0.020 mg/sample < 0.088 ppm 1300 Methylene chloride < 0.020 mg/sample < 0.060 ppm 1005 Hexane < 0.020 mg/sample < 0.059 ppm 1500 Chloroform < 0.020 mg/sample < 0.043 ppm 1003 Methyl chloroform < 0.020 mg/sample < 0.038 ppm 1003 total other A Hydrocarbons < 0.020 mg/sample < 0.059 ppm 1500 Benzene < 0.020 mg/sample < 0.065 ppm 1501 1,2-Dichloroethane c 0.020 mg/sample < 0.051 ppm 1003 Trichloroethylene < 0.020 mg/sample < 0.039 ppm 1022 Toluene < 0.020 mg/sample < 0.055 ppm 1501 PCE (Tetrachloroefhene) < 0.020 mg/sample < 0.031 ppm 1003 Chlorobenzene < 0.020 mg/sample < 0.045 ppm 1003 Ethylbenzene < 0.020 mg/sample < 0.048 ppm 1501 Styrene < 0.020 mg/sample < 0.049 ppm 1501 Cumene (Isopropylbenzene) < 0.020 mg/sample < 0.042 ppm 1501 Xylenes, Total < 0.020 mg/sample < 0.048 ppm 1501 total other B Hydrocarbons < 0.020 mg/sample < 0.055 ppm 1501
ATC-0123-STV-VOC 2 Air Volume: 96 L Lab Sample; 1476666
Pentane < 0.020 mg/sample < 0.071 ppm 1500 Acetone < 0.020 mg/sample < 0.088 ppm 1300 Methylene chloride < 0.020 mg/sample < 0.060 ppm 1005 Hexane < 0.020 mg/sample < 0.059 ppm 1500
4418 POTTSVILLE PIKE. READING, PENNSYLVANIA 19605 ' 610-921-8833 FAX 610-921-9667
I
CITY_21MC100_002897119
NYC-WTC_000401309
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000401298
ATC analytical report for 19125-0246; samples collected 12/20/01.
7 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312630
Analytical report for HC A&B on samples collected Jan 30, 2002 for ATC project.
8 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238089
Document tracking the chain of custody for an air sample collected on January 23, 2002, for pentane analysis.
8 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312564
Analytical results for hydrocarbons; ATC 208511, November 21–27, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272100
Industrial hygiene lab results for ATC project 19125-0246.
8 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314456
Analytical report for ATC; HC Scan A&B, client ATC [name].
8 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238075
Cover page for an industrial hygiene and environmental testing analytical report received in December 2001.
7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396083
Analytical report for hydrocarbon tests conducted for ATC Associates, NYC school.
8 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312636
Analytical report for ATC project, samples collected 12-20-01.
7 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373553
Analytical report to ATC client 209440; intake 24-01-02, 28-01-02.
8 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312560
Analytical report for ATC samples; Received Nov 15, Reported Nov 20, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272096
Industrial hygiene analytical report for ATC project 19125-0246, samples 20-Nov-01
8 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000238089
Document tracking the chain of custody for an air sample collected on January 23, 2002, for pentane analysis.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312630
Analytical report for HC A&B on samples collected Jan 30, 2002 for ATC project.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238075
Cover page for an industrial hygiene and environmental testing analytical report received in December 2001.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401298
ATC analytical report for 19125-0246; samples collected 12/20/01.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238061
Cover page for an industrial hygiene and environmental testing analytical report received in December 2001 and reported January 2002.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238057
Cover page for an industrial hygiene and environmental testing analytical report received in December 2001.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000401298
ATC analytical report for 19125-0246; samples collected 12/20/01.
Similar indexed content
NYC-WTC_000312630
Analytical report for HC A&B on samples collected Jan 30, 2002 for ATC project.
Similar indexed content
NYC-WTC_000238089
Document tracking the chain of custody for an air sample collected on January 23, 2002, for pentane analysis.
Similar indexed content
Analytical results for hydrocarbons; ATC 208511, November 21–27, 2001.
Similar indexed content
NYC-WTC_000272100
Industrial hygiene lab results for ATC project 19125-0246.
Similar indexed content