NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air sampling for silica, Stuyvesant HS, Feb 2002

Machine-extracted title · confidence 42%

Letter report of silica air sampling conducted January 30, 2002 at Stuyvesant High School.

NYC-WTC_000401230–000401231
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York, New York 10010 www.atc- en viro .com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

February 18, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-1 TQueens Plaza North Long Island City, NY 11101

Re: Air Sampling for Silica Stuyvesant High School ATC Project No. 15-19125-0246

Dear Mr. Orlan;

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for silica- containing dust conducted on January 30, 2002, at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of H. A. Bader, a consultant to the parents’ association.

ATC collected twelve (12) samples for respirable dust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. One (1) outdoor sample and eleven (11) indoor samples were collected per day. The samples, plus one blank, were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. Analysis was performed by x-ray diffraction according to OSHA Method 142. A copy of the analytical report is attached.

The Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL) for silica-containing dust is based on the percent of quartz (SiOi) found in the dust, the higher the percentage of quartz, the lower the PEL. The formula for calculating the PEL is found in 29 CFR 1910.1000, Table Z-3. The formula is:

lOmg/m^ %SiO2 + 2

Silica was found above the limits of detection in one sample. Sample #S11, collected in Room 940, contained 0.0147 milligrams of silica per cubic meter of air (mg/m^). The amount of quartz in this sample was <24%, therefore the PEL for this dust would be:

lOmg/m^ = 0.385 mg/m^ 24 + 2

The silica concentration in this sample was 3.8% of the calculated PEL.

CITY_21MC100_002897013

NYC-WTC_000401230

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000401230Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000226997

Report letter from ATC Associates detailing air sampling for silica-containing dust conducted at Stuyvesant High School.

Similar indexed content

NYC-WTC_000175068

ATC Associates report on air sampling for silica-containing dust conducted at Stuyvesant High School on January 30, 2002.

Similar indexed content

Compare copies and versions →