NYC 9/11 Public Portal Document
‘ Feb 22 02 04:51p PSC Rnalbtical Services G109219B67 p. 5
INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING
•EPAJNVLAP101262-0 •NY DOHINEIAC 10903 •NJDEP PA020
• AIHA ACCREDITATION NO. 10M39 ■PADEPOe-353 «CT DPH PH-0238
•NCDENR 539
Analytical Results
ANALYTICAL SERVICES
for
ATC Associates
WorkOrder: R02020568
Client Reference; 19125-0246
Analyte Concentration bimit of Test Date Analyzed
Detection Method /Analyst
(ug) : (mg/nP) ; (PPni) (ug)
Client ID: ATC-0213-STUY-M3 bab ID: -03A Date Sampled: 2/13/02 Matrix: Filter Air Vol.(b): 9(50
Aluminum <1.00 <0.00104 1 N7300 MCE 02/21/2002 AJB
Cadmium <0.200 <0.000208 0.2 N7300 MCE 02/21/2002 AJB
Chromium 0.502 0.000523 0.2 N7300 MCE 02/21/2002 AJB
Cobalt <0.100 <0.000104 0.1 N7300 MCE 02/21/2002 AJB
Copper <0.200 <0.000208 0.2 N7300 MCE 02/21/2002 AJB
Iron <2.00 <0.00208 2 N7300 MCE 02/21/2002 AJB
Magnesium <1.30 <0.00135 1.3 N730Q MCE 02/21/2002 AJB
•t
Manganese <0.300 <0.000312 0.3 N7300 MCE 02/21/2002 AJB
Molybdenum <1.00 <0.00104 1 N7300 MCE 02/21/2002 AJB
Nickel <0.200 <0.000208 0.2 N7300 MCE 02/21/2002 AJB
Zinc <0.500 <0.000521 0.5 N7300 MCE 02/21/2002 AJB
Client ID: ATC-02i 3-STUY-M4 LabID:.04A Date Sampled: 2/13/02 Matrix: Filter Air Vol.(b): NA
Aluminum <1.00 1 N7300 MCE 02/21/2002 AJB
Cadmium <0.200 0.2 N7300 MCE 02/21/2002 AJB
Chromium 0.563 0.2 N7300 MCE 02/21/2002 AJB
Cobalt <0.100 0.1 N7300 MCE 02/21/2002 AJB
Copper <0.200 0.2 N7300 MCE 02/21/2002 AJB
Iron ■ 10.1 2 N7300 MCE 02/21/2002 AJB
Magnesium <1.30 1.3 N7300 MCE 02/21/2002 AJB
Manganese <0.300 0.3 N7300 MCE 02/21/2002 AJB
Molybdenum <1.00 1 N7300 MCE 02/21/2002 AJB
Nickel <0.200 0.2 N7300 MCE 02/21/2002 AJB
Zinc <0.500 0.5 N7300 MCE 02/21/2002 AJB
(a) Analysis indicates possible breakthrough; back section result is greater than 0%of the front section result.
General Notes:
<; Less than the indicated limit of detection (LOD).
Information not available or not applicable..
Back sections were checked and showed no significant breakthrough.
Page 2 of 2