NYC 9/11 Public Portal Document
Mar 04 02 D3:23f> PSC Hnalbtical Services 6109219667 p. 5
INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING
•EPA/NVLAP 101262-0 •NY OOHNELAC 10903 •NJ OEP PAC’D
• AIHA ACCREDITATION NO. 10043B • PA DEP 06-363 •CTDPH PH-02J8
•NC DENR 699
.Analytical Results
ANALYTICAL SERVICES
for
ATC Associates
WorkOrder: RO202O956
Client Reference: 19125-0289
Analyte Concentration Limit of Test Date Analyzed
Detection Method /Analyst ;
(ug) : ■ (ppm) (ug)
Client ID: MS A'rC-0225-l50M Lab ID: -03A Date Sampled: 2/25/02 Matrix: Filter Air Vol.(L): 1200
Aluminum <1.00 <0.000833 1 N7300 MCE 03/03/2002 AJB
Cadmium <0.200 <0.000167 0.2 N7300 MCE 03/03/2002 AJB
Chromium 0.440 0.000366 0.2 N7300 MCE 03/03/2002 AJB
Cobalt <0.100 <0.0000833 0.1 N7300 MCE 03/03/2002 AJB
Copper <0.200 <0.000167 0,2 N7300 MCE 03/03/2002 AJB
Iron <2.00 <0.00167 2 N7300 MCE 03/03/2002 AJB
M.ignesium <1.30 <0.00108 1.3 N7300 MCE 03/03/2002 AJB
Manganese <0.300 <0.000250 0.3 N7300 MCE 03/03/2002 AJB
Molybdenum <1.00 <0.000833 1 N7300 MCE 03/03/2002 AJB
Nickel <0.200 <0.000167 0.2 N7300 MCE 03/03/2002 AJB
2ilic <0.500 <0.000417 0.5 N7300 MCE 03/03/2002 AJB
Client ID: M4 ATC-0225-150M Lab ID; -04A Date Sampled: 2/25/02 Matrix: Filter Air Vol.(L): NA
Aluminum <1.00 1 IM7300 MCE 03/03/2002 AJB
Cadmium <0.200 0.2 N7300 MCE 03/03/2002 AJB
Chromium 0.387 0.2 N7300 MCE 03/03/2002 AJB
Cobalt <0.100 0.1 N7300 MCE 03/03/2002 AJB
Copper <0.200 0.2 N730O MCE 03/03/2002 AJB
Iron <2.00 2 N7300 MCE 03/03/2002 AJB
Magnesium <1.30 1.3 N7300 MCE 03/03/2002 AJB
Manganese <0.300 0.3 N73O0 MCE 03/03/2002 AJB
Molybdenum <1.00 1 N7300 MCE 03/03/2002 AJB
Nickel <0.200 0.2 N73O0 MCE 03/03/2002 AJB
Zinc <0.500 0.5 N730O MCE 03/03/2002 AJB
(aj Anatys.is. indicates possible breakthrough; back section result is greater than 0% of the front section result.
General Notes:
<: Less than the indicated limit of detection (LOD).
Information not available or not applicable.
Back sections were checked and showed no significant breakthrough.
Page 2 of 2
CITY_21MC100_003067911
NYC-WTC_000334648
OCR can misread numbers and units. Confirm readings against the page image before using them.