Mr. Bernard P. Orlan March 1, 2002 Air Sampling for Metals Page 2 Stuwesant High School ATC Protect No. 15-19125-0246

RESULTS

Chromium was detected in all of the samples obtained (including the blank). Blank-correcting the samples will lower the chromiiun concentrations to below the limit of detection of the analytical method.

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium in air of 0.6 ug/m^, this assumes a continuous exposure for one year. The samples here were analyzed for total chromium (trivalent and hexavalent). Blank-corrected chromium concentrations are well below the EPA level.

Copper was detected at 0.295 micrograms, which is slightly above the analytical limit of detection of 0.2 micrograms in the sample collected at the 2“^ floor bridge entrance hallway (Sample #ATC-0213-STUY-M2). The resulting calculated airborne concentration at the location was 0.308 micrograms per cubic meter of air. Copper was not detected in the blank above the analytical limit of detection; The EPA has not established a screening limit or guideline for copper.

No other metals were detected in the samples above the limit of detection for the analytical method. s’

ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.

Sincerely, ATC Associates, Inc.

James R. Cohn, CIH, CSP Regional Manager Industrial Hygiene Division

Attachment

CITY_21MC100_002896929

NYC-WTC_000401171

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000401171Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000238197

Letter report from ATC Associates detailing air sampling for metals conducted at Stuyvesant High School on February 13, 2002.

Similar indexed content

NYC-WTC_000238173

Letter report from ATC Associates detailing air sampling for metals in airborne dust at Stuyvesant High School on January 17, 2002.

Similar indexed content

NYC-WTC_000238203

Letter report from ATC Associates detailing air sampling for metals conducted at Stuyvesant High School on February 20, 2002.

Similar indexed content

Compare copies and versions →